1998
DOI: 10.1016/s0003-2670(98)00294-3
|View full text |Cite
|
Sign up to set email alerts
|

Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
90
0
4

Year Published

2005
2005
2016
2016

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 131 publications
(94 citation statements)
references
References 28 publications
0
90
0
4
Order By: Relevance
“…Pre-concentration on solid sorbents followed by thermal desorption (TD) is the most frequent method for the analysis of VOCs in breath samples [9][10][11][12][13]16,[19][20][21][22][23][24][25][26][27][28][43][44][45]47,55,62,75,[81][82][83][84][85]95,96]. Sorbent traps present the advantages that they can be prepared on a micro-scale and coupled on-line with a GC system to allow near real-time measurements [97][98][99][100][101], and the sorbent configuration can be easily changed to adapt to different compounds.…”
Section: Concentration On Solid Sorbentsmentioning
confidence: 99%
“…Pre-concentration on solid sorbents followed by thermal desorption (TD) is the most frequent method for the analysis of VOCs in breath samples [9][10][11][12][13]16,[19][20][21][22][23][24][25][26][27][28][43][44][45]47,55,62,75,[81][82][83][84][85]95,96]. Sorbent traps present the advantages that they can be prepared on a micro-scale and coupled on-line with a GC system to allow near real-time measurements [97][98][99][100][101], and the sorbent configuration can be easily changed to adapt to different compounds.…”
Section: Concentration On Solid Sorbentsmentioning
confidence: 99%
“…They have analyzed through a preconcentration system, [17] [ 18] 36 the air exhaled by a patient while knowing that the appearance of some gas molecules in exhaled air is 37 characteristic of the metabolism, thus the state of patient's health. The presence of some of these VOCs is…”
mentioning
confidence: 99%
“…That is why pre-concentration of the sample is frequently required to extract useful signals. Such things increase both the time and cost of the analysis [18] [19]. It should be noted that there are many extraneous sources of volatile metabolites that can cause distortion of the "olfactory image" registered by E-nose.…”
Section: Introductionmentioning
confidence: 99%