2018
DOI: 10.1016/j.iccl.2017.12.001
|View full text |Cite
|
Sign up to set email alerts
|

Anatomy and Physiologic Roles of the Left Atrial Appendage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 101 publications
0
4
0
1
Order By: Relevance
“…Therefore, when surgically closing the LAA, care must be taken not to involve the LCX. However, since the LAA has multiple morphologies, its position in relation to the surrounding structures varies, and there are many patients in whom the distance between the LMT and the LAA orifice is closer than 10 mm [ 6 ]. Another case of stenosis of the LMT after LAA clipping has been reported, but this was due to the surgeons’ difficulty in obtaining a clear view during laparoscopic surgery [ 4 ].…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, when surgically closing the LAA, care must be taken not to involve the LCX. However, since the LAA has multiple morphologies, its position in relation to the surrounding structures varies, and there are many patients in whom the distance between the LMT and the LAA orifice is closer than 10 mm [ 6 ]. Another case of stenosis of the LMT after LAA clipping has been reported, but this was due to the surgeons’ difficulty in obtaining a clear view during laparoscopic surgery [ 4 ].…”
Section: Discussionmentioning
confidence: 99%
“…The role of TEE in the sizing of LAA occluders has been studied for many years. Moreover, different LAA occluders have different sizing parameters ( 17 , 21 ). Both 2D-TEE (the maximum orifice diameter) and 3D-TEE (the maximum orifice diameter, area- or perimeter-derived circumferential orifice diameter) have been effectively used for occlusion sizing.…”
Section: Discussionmentioning
confidence: 99%
“…It is not yet known whether the commonly used landmarks (the LCX and the highest point of the Coumadin ridge) for TEE assessment in LAA orifice measurement during LAA occlusion are suitable for LAA clipping devices. Currently, the sizing parameters based on the landmarks among different LAA occluders are quite different ( 17 , 21 ). In our experience, these two procedures (the intracardiac vs .…”
Section: Discussionmentioning
confidence: 99%
“…Recently, a meta-analysis comparing Watchman and Amplatzer devices for stroke protection resulted in similar low complication and event rates findings with comparable efficacy and safety results [23]. There are also many other emerging LAA mechanical device technologies in various stages of pre-clinical development [24][25][26][27][28].…”
Section: Discussionmentioning
confidence: 99%