1999
DOI: 10.1016/s0021-9673(99)00383-0
|View full text |Cite
|
Sign up to set email alerts
|

Anthracycline analysis by capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 42 publications
(24 citation statements)
references
References 20 publications
0
24
0
Order By: Relevance
“…Although the focus of this review is on chromatographic techniques, it needs to be mentioned that also capillary electrophoresis with UV [84], amperometric [85] and laser-induced fluorescence detection [86][87][88][89][90][91][92] and other techniques [93,94] have been described. The majority of these methods have been reviewed elsewhere [16,17].…”
Section: Non-chromatographic Techniquesmentioning
confidence: 99%
“…Although the focus of this review is on chromatographic techniques, it needs to be mentioned that also capillary electrophoresis with UV [84], amperometric [85] and laser-induced fluorescence detection [86][87][88][89][90][91][92] and other techniques [93,94] have been described. The majority of these methods have been reviewed elsewhere [16,17].…”
Section: Non-chromatographic Techniquesmentioning
confidence: 99%
“…A migration solution containing 30% (v/v) acetonitrile was used in a similar separation of DOX, IDA and DNR 39 using CE-LIF. Separations of DOX and DNR after extraction, were reported by Simeon et al 40 and Hempel et al 41 in the determination of anthracyclines in plasma and tumors. Similar work employing cyclodextrin (CD)-assisted MEKC on the separation of DOX and doxorubicinol was reported by Eder et al 42 It should be mentioned that the aforementioned CE methods used organic solvents, which are known to precipitate proteins in biological samples, either during separation or extraction.…”
Section: Direct Determination Of Anthracyclines By Mekc-lifmentioning
confidence: 87%
“…339 LC-ELSD was also applied for the analysis of daunorubicin and its degradation products for a stability study of injectable solution of anthracycline (0.25 mg mL −1 was the lowest concentration of standard solutions tested), but the interest of ELSD for anthracyclines is not obvious since these molecules can be easily detected by UV, FD and MS. 340 As already mentioned, CE was another separation technique widely used for the determination of anthracyclines. LIF detection [341][342][343][344][345][346][347][348][349] is usually preferred to UV detection 350 to improve sensitivity. However, the poor UV sensitivity observed in CE (due to the narrow optical path of the capillaries) can be compensated for by a sweeping preconcentration step and an electrokinetic injection.…”
Section: Intercalating Agentsmentioning
confidence: 99%