2016 Progress in Applied Electrical Engineering (PAEE) 2016
DOI: 10.1109/paee.2016.7605113
|View full text |Cite
|
Sign up to set email alerts
|

Anti-shock safety of industrial electric installations with built-in frequency converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 2 publications
0
3
0
1
Order By: Relevance
“…The inability to determine the impedance of the phaseto-ground short circuit at the FC output if the protective device is connected in the common part of the network complicates the construction of protection devices [7]. Erroneous operation of regular ground fault protection devices can also be caused by the semiconductor converter as a part of the mine section electrical network [8].…”
Section: Literature Review and Problem Statementmentioning
confidence: 99%
See 1 more Smart Citation
“…The inability to determine the impedance of the phaseto-ground short circuit at the FC output if the protective device is connected in the common part of the network complicates the construction of protection devices [7]. Erroneous operation of regular ground fault protection devices can also be caused by the semiconductor converter as a part of the mine section electrical network [8].…”
Section: Literature Review and Problem Statementmentioning
confidence: 99%
“…and the submatrix7 F is zero due to the disconnect between inductive edges and resistive chords.Based on Kirchhoff's laws, matrix equations are compiled to calculate the vectors of currents of resistive edges I Red and voltages of resistive chords U Rch :Taking into account Ohm's law for resistive edges and chords, the equation that enables to calculate the vector I R =[I Red I Rch ] T of the resistive elements currents is possible to obtain from (12):…”
mentioning
confidence: 99%
“…To protect against leakages, the low-voltage power networks of the mine are equipped with a protective device. However, a leakage current to the ground in the cable, that connects the motor to the FC, cannot be detected by such a device with satisfactory reliability [1]. This determines the relevance of the scientific and technical problem of increasing the electrical safety of underground combined power networks.…”
Section: Introductionmentioning
confidence: 99%
“…Для захисту від витоків струму на землю низьковольтні електромережі шахти обладнують апаратом захисту від витоків струму на землю (наприклад, АЗУР-4пп). Проте витік струму на землю в кабелі, що під'єднує двигун до ПЧ, не може бути з достатньою надійністю виявлений загальномережевим апаратом захисту [1]. Причина полягає у викривленні постійного оперативного струму, що накладається на мережу апаратом захисту з метою контролю опору ізоляції, напівпровідниковими елементами ПЧ [2].…”
unclassified