1999
DOI: 10.3171/jns.1999.91.2.0231
|View full text |Cite
|
Sign up to set email alerts
|

Application of a rigid endoscope to the microsurgical management of 54 cerebral aneurysms: results in 48 patients

Abstract: It is the authors' impression that the use of the endoscope in the microsurgical management of cerebral aneurysms enhanced the safety and reliability of the surgery. However, there is a prerequisite for the surgeon to be familiar with this instrumentation and fully prepared for the risks and inconveniences of endoscopic procedures.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
54
0
4

Year Published

2005
2005
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 86 publications
(58 citation statements)
references
References 13 publications
0
54
0
4
Order By: Relevance
“…Post-clipping evaluation ensures that the aneurysm is completely obliterated, and the perforating vessels and surrounding neural structures are intact where the clip may obstruct direct microscopic view. 33,34 Several case series have evaluated the usefulness of endoscopy assistance for aneurysm surgery in association with PTC. 33,37,38,40 Greater anatomic clarification was identified with endoscopy in 81.5% to 94.9% of aneurysms, but interestingly, information obtained exclusively through endoscopy was found in only 16.7% to 19.0% of aneurysms.…”
Section: Endosope-assisted Aneurysm Surgerymentioning
confidence: 99%
See 3 more Smart Citations
“…Post-clipping evaluation ensures that the aneurysm is completely obliterated, and the perforating vessels and surrounding neural structures are intact where the clip may obstruct direct microscopic view. 33,34 Several case series have evaluated the usefulness of endoscopy assistance for aneurysm surgery in association with PTC. 33,37,38,40 Greater anatomic clarification was identified with endoscopy in 81.5% to 94.9% of aneurysms, but interestingly, information obtained exclusively through endoscopy was found in only 16.7% to 19.0% of aneurysms.…”
Section: Endosope-assisted Aneurysm Surgerymentioning
confidence: 99%
“…34 Therefore, they may complement the standard operating microscope, which is restricted to illumination and magnification along a line of sight. 33 From a neuroanatomical perspective, the endoscope is ideal for visualizing aneurysms arising medially from the ICA, where the direct line of sight is obstructed by ICA or optic apparatus. 35 Using 0°-and 45°-4 mm and 30°-2.7 mm endoscopes on cadaveric specimens, Peris-Celda et al evaluated the additional endoscopic exposure and available working room at common aneurysm sites.…”
Section: Endosope-assisted Aneurysm Surgerymentioning
confidence: 99%
See 2 more Smart Citations
“…1,4,5,11) The advantages of this so-called``endoscope-assisted microsurgery'' 3) include increased light intensity, clear depiction of details in close-up positions, and extended viewing angle. 7) Both microscopic and endoscopic images must be monitored simultaneously during the procedure to obtain more complete information from the surgical field and to avoid inadvertent tissue injury due to inaccurate handling of the endoscope.…”
Section: Introductionmentioning
confidence: 99%