1998
DOI: 10.1016/s0013-4694(98)00092-3
|View full text |Cite
|
Sign up to set email alerts
|

Assessing the accuracy of topographic EEG mapping for determining local brain function

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
192
0
1

Year Published

2002
2002
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 277 publications
(199 citation statements)
references
References 25 publications
6
192
0
1
Order By: Relevance
“…ization and integration of absolute and relative power values from all electrode sites for a given EEG recording; cordance values are calculated in three steps. First, EEG power values are computed using a re-attributional electrode montage in which power values from pairs of electrodes that share a common electrode are averaged together to yield the re-attributed power (Figure 2) (Cook et al 1998b). For example, to determine a power value for the brain region underlying the F4 electrode, one first computes power spectra for the channels that include the F4 electrode (i.e., F4-F8, F4-AF2, F4-FC2, and F4-FC6, in Figure 2), and then averages the absolute power values from those channels to obtain the reattributed power for the F4 electrode.…”
Section: Cordance Calculationsmentioning
confidence: 99%
See 1 more Smart Citation
“…ization and integration of absolute and relative power values from all electrode sites for a given EEG recording; cordance values are calculated in three steps. First, EEG power values are computed using a re-attributional electrode montage in which power values from pairs of electrodes that share a common electrode are averaged together to yield the re-attributed power (Figure 2) (Cook et al 1998b). For example, to determine a power value for the brain region underlying the F4 electrode, one first computes power spectra for the channels that include the F4 electrode (i.e., F4-F8, F4-AF2, F4-FC2, and F4-FC6, in Figure 2), and then averages the absolute power values from those channels to obtain the reattributed power for the F4 electrode.…”
Section: Cordance Calculationsmentioning
confidence: 99%
“…This is somewhat similar to the single source method of Hjorth (1970Hjorth ( , 1975, but cordance recombines the power values whereas Hjorth's method recombines voltage signals by averaging signal amplitudes from pairs of electrodes. The Hjorth method is preferred under many experimental designs, particular when the source of a signal is the question of interest (e.g., seizure focus); the re-attributional montage provides a higher association between QEEG measures and regional cortical perfusion than does the Hjorth method (Cook et al 1998b) and so offers an advantage for testing our specific hypotheses. Relative power is calculated in the conventional manner, as the percentage of power in each band, relative to the total spectrum considered (here, 0.5 Hz to 20 Hz) (cf.…”
mentioning
confidence: 99%
“…Brain electrical activity can be measured using cordance, low-resolution brain electromagnetic tomography (LORETA), and antidepressant treatment (ATR) index. Cordance, which uses QEEG measurements conducted from a full scalp electrode array, assesses perfusion of cerebral cortex and brain activity on cortical convexities like PFC (Cook et al, 1998;Leuchter et al, 1999). Several groups have demonstrated the usefulness of cordance in characterizing antidepressant response (Bares et al, 2008;Cook et al, 2002).…”
Section: Neurostructural and Neurofunctional Studiesmentioning
confidence: 99%
“…EEG recordings were performed using the QND system (Neurodata, Inc., Pasadena, CA) while subjects rested in the eyes-closed, maximally alert state in a sound-attenuated room with subdued lighting, using procedures previously described in detail (Cook et al, 1998bLeuchter et al, 1992). Electrodes were placed with an electrode cap (ElectroCap; Eaton, OH) using an extended International 10-20 System with 35 recording electrodes ( Figure 1; Cook et al, 1998b).…”
Section: Qeeg Techniquesmentioning
confidence: 99%
“…Electrodes were placed with an electrode cap (ElectroCap; Eaton, OH) using an extended International 10-20 System with 35 recording electrodes ( Figure 1; Cook et al, 1998b). Eye movements were monitored with right infraorbital and left outer canthus electrodes.…”
Section: Qeeg Techniquesmentioning
confidence: 99%