Anais Do XIV Workshop Em Desempenho De Sistemas Computacionais E De Comunicação (WPerformance 2015) 2015
DOI: 10.5753/wperformance.2015.10394
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação Comparativa de Escalabilidade de Aplicações de Alto Desempenho em Cluster Físico e na Nuvem

Abstract: A análise de desempenho de aplicações de computação de alto desempenho (HPC) foi recentemente facilitada pelo uso de plataformas de nuvem. Os subsídios concedidos pelos fornecedores de infra-estrutura para projetos de pesquisa nas universidades também tem contribuído neste sentido. No entanto, o desempenho de aplicativos HPC depende fortemente do suporte de Entrada/Saída da plataforma, principalmente da rede de intercomunicação entre as máquinas virtuais. Neste estudo, o desempenho de aplicativos selecionados … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 10 publications
0
0
0
Order By: Relevance
“…Like the Stress wave, the propagation of waves by the ultrasonic method in woods presents itself as a rather complex phenomenon. The evaluation of existing wooden structures using the ultrasound technique is characterized by a high variability in the results (OLIVEIRA et al, 2015). The where, L is the length of the part, in meters, and t is the propagation time of the wave, in seconds.…”
Section: Ultrasoundmentioning
confidence: 99%
See 1 more Smart Citation
“…Like the Stress wave, the propagation of waves by the ultrasonic method in woods presents itself as a rather complex phenomenon. The evaluation of existing wooden structures using the ultrasound technique is characterized by a high variability in the results (OLIVEIRA et al, 2015). The where, L is the length of the part, in meters, and t is the propagation time of the wave, in seconds.…”
Section: Ultrasoundmentioning
confidence: 99%
“…The performance of the ultrasum m technique was verified in the mechanical evaluation of sawn beams of the Brown species (Castanea sativa Mill.) that were removed from a building under renovation (OLIVEIRA;. To compare the effectiveness of the use of wave frequencies of 24 kHz and 54 kHz in the characterization of the modulus of elasticity and the flexural strength, different arrangements of the probes, coupling materials and test schemes were considered.…”
Section: Ultrasoundmentioning
confidence: 99%