1996
DOI: 10.1016/0039-9140(95)01780-1
|View full text |Cite
|
Sign up to set email alerts
|

Behaviour of the dithiocarbamate complexes of arsenic, antimony, bismuth, mercury, lead, tin and selenium in methanol with a hydride generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2004
2004
2012
2012

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(13 citation statements)
references
References 6 publications
0
13
0
Order By: Relevance
“…The obtained detection limit was also comparable with those obtained by other more sophisticated techniques and manifolds or expensive sorbent materials. So the detection limit obtained by Vuchkova et al [38] was 30 ng ml −1 by mean the preconcentration and ICP determination of Pb(II) in water samples using dithiocarbamate in methanol. Future research can be focused on testing the ability of TS-gel and its performance for on-line determination of other metals with other detection techniques more sensitive than ICP-AES technique with a neumatic nebulizer.…”
Section: Discussionmentioning
confidence: 92%
See 1 more Smart Citation
“…The obtained detection limit was also comparable with those obtained by other more sophisticated techniques and manifolds or expensive sorbent materials. So the detection limit obtained by Vuchkova et al [38] was 30 ng ml −1 by mean the preconcentration and ICP determination of Pb(II) in water samples using dithiocarbamate in methanol. Future research can be focused on testing the ability of TS-gel and its performance for on-line determination of other metals with other detection techniques more sensitive than ICP-AES technique with a neumatic nebulizer.…”
Section: Discussionmentioning
confidence: 92%
“…The most important improvements are derived from the fact from working in closed systems whose requirements on the laboratory environment for trace analysis are much less stringent, reduced consumption of reagent and high sampling frequencies what justifies the current trend toward an increase in the use of these preconcentration techniques. Arpadjan and co-workers [14,15] applied column solid-phase extraction using dithiocarbamate-loaded polyurethane foam to the preconcentration of lead. Nevertheless, in addition to the need to introduce an organic solvent (which requires a careful control of the experimental parameters) to dissolve the lead-dithiocarbamate complex, this technique is time-consuming because a new column have to be prepared for each experiment.…”
Section: Introductionmentioning
confidence: 99%
“…[29] Hydrochloric acid solution with saturated boric acid was often employed as the carrier solution to reduce the competition for free radicals from Se 4þ . [29] Hydrochloric acid solution with saturated boric acid was often employed as the carrier solution to reduce the competition for free radicals from Se 4þ .…”
Section: Effect Of Carrier Solution Hcl Solutionmentioning
confidence: 99%
“…Due to such wide concentration level of arsenic as well as its considerable toxicity, a great number of techniques for arsenic determination have been applied [3][4][5][6][7][8][9] sense a technique commonly used is hydride generation (HG). It allows low detection limits and has found wide applications in the determination of trace levels of arsenic combined with atomic absorption spectrometry [10][11][12], atomic fluorescence spectrometry (AFS) [13][14][15] or coupled with optical emission spectroscopy-inductively coupled plasma (ICP-OES) [16][17][18][19][20][21].…”
Section: Introductionmentioning
confidence: 99%
“…Several on-line solid phase extraction (SPE) methodologies have been developed, and the majority of them employs ionic exchange resins [19,23,24], modified silica gel [25][26][27], coated polyurethane foam [19], ethyl vinyl acetate (EVA) knotted reactors [28][29][30], PTFE knotted reactors [31,32] and PTFE turning-packed mini-columns [20], among others adsorbent materials.…”
Section: Introductionmentioning
confidence: 99%