2008
DOI: 10.1016/j.jpowsour.2008.03.062
|View full text |Cite
|
Sign up to set email alerts
|

Biocatalyzed hydrogen production in a continuous flow microbial fuel cell with a gas phase cathode

Abstract: Biocatalyzed hydrogen production in a continuous flow microbial fuel cell with a gas phase cathode Tartakovsky, B.; Manuel, M.-F.; Neburchilov, V.; Wang, H.; Guiot, S. R.Contact us / Contactez nous: nparc.cisti@nrc-cnrc.gc.ca. abstractA single liquid chamber microbial fuel cell (MFC) with a gas-collection compartment was continuously operated under electrically assisted conditions for hydrogen production. Graphite felt was used for anode construction, while the cathode was made of Pd/Pt coated Toray carbon fi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
86
2
3

Year Published

2010
2010
2020
2020

Publication Types

Select...
5
3

Relationship

4
4

Authors

Journals

citations
Cited by 116 publications
(94 citation statements)
references
References 16 publications
3
86
2
3
Order By: Relevance
“…The carbon source stock solution contained (in g L À1 ): sodium acetate (55.2), yeast extract (0.8), NH 4 Cl (18.7), KCl (148), K 2 HPO 4 (64), and KH 2 PO 4 (40.6). The dilution water contained 1 mL of a trace metals (TM) stock solution prepared according to Tartakovsky et al (2008). The carbon source solution was fed at a rate of 5-10 mL d À1 with a syringe pump.…”
Section: Mec Construction and Operationmentioning
confidence: 99%
“…The carbon source stock solution contained (in g L À1 ): sodium acetate (55.2), yeast extract (0.8), NH 4 Cl (18.7), KCl (148), K 2 HPO 4 (64), and KH 2 PO 4 (40.6). The dilution water contained 1 mL of a trace metals (TM) stock solution prepared according to Tartakovsky et al (2008). The carbon source solution was fed at a rate of 5-10 mL d À1 with a syringe pump.…”
Section: Mec Construction and Operationmentioning
confidence: 99%
“…The anode and cathode were separated by a 0.7 mm thick J-cloth, as suggested by Fan et al [19]. More details on MEC design can be found elsewhere [11,20].…”
Section: Mec Constructionmentioning
confidence: 99%
“…MEC temperature was maintained at 30 • C by a heating plate secured on the anodic compartment side of the MEC. More details on MEC operation can be found elsewhere [11,20].…”
Section: Mec Operation and Characterizationmentioning
confidence: 99%
See 1 more Smart Citation
“…Gas composition was measured using a 6890 Series gas chromatograph (Hewlett Packard, Wilmington, DE, USA). More details can be found elsewhere [5].…”
Section: Introductionmentioning
confidence: 99%