2014
DOI: 10.1016/j.ultras.2013.11.003
|View full text |Cite
|
Sign up to set email alerts
|

Bolt axial stress measurement based on a mode-converted ultrasound method using an electromagnetic acoustic transducer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 65 publications
(26 citation statements)
references
References 18 publications
0
25
0
1
Order By: Relevance
“…The idea of bolt force monitoring discussed in this paper is based on measurements of elastic waves. It was confirmed by Kim and Hong [14] and Ding et al [15] that even a relatively small change in a bolt force will affect the signals measured (its time of flight, amplitude, frequency, etc.). Changes in the tension force have an influence on the shortening/elongation of the screw.…”
Section: The Idea Of Force Monitoring In Boltsmentioning
confidence: 80%
“…The idea of bolt force monitoring discussed in this paper is based on measurements of elastic waves. It was confirmed by Kim and Hong [14] and Ding et al [15] that even a relatively small change in a bolt force will affect the signals measured (its time of flight, amplitude, frequency, etc.). Changes in the tension force have an influence on the shortening/elongation of the screw.…”
Section: The Idea Of Force Monitoring In Boltsmentioning
confidence: 80%
“…It has been observed that this method provides sufficient resolution to estimate an axial stress less than 10% of the yield stress of the material with a maximum error of 5%. Ding et al [49,50] used the electromagnetic acoustic transducer (EMAT) to generate a transverse wave at the end of the bolt and obtained the longitudinal wave from the reflection of the transverse wave using mode conversion, as shown in Figure 12. In this figure, the bolt is simplified as a cylindrical specimen, S 1 is the path of the incident transverse wave, S 2 is the path of the reflected transverse wave, S 3 is the path of the reflected longitudinal wave, α T is the emission angle of the incident transverse wave, θ T is the incident angle of the incident transverse wave, γ T is the reflection angle of the reflected transverse wave, and γ L is the reflection angle of the reflected longitudinal wave.…”
Section: The Bi-wave Methodsmentioning
confidence: 99%
“…In this figure, the bolt is simplified as a cylindrical specimen, S 1 is the path of the incident transverse wave, S 2 is the path of the reflected transverse wave, S 3 is the path of the reflected longitudinal wave, α T is the emission angle of the incident transverse wave, θ T is the incident angle of the incident transverse wave, γ T is the reflection angle of the reflected transverse wave, and γ L is the reflection angle of the reflected longitudinal wave. Through the path analysis of the mode-converted ultrasound, the following theoretical model was established [49]:…”
Section: The Bi-wave Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A self-developed EMAT testing system is utilized [ 35 ]. The experimental setup is schematically illustrated in Figure 11 .…”
Section: Experimental Investigation Of the Proposed Ematsmentioning
confidence: 99%