2021
DOI: 10.1016/j.colsurfa.2020.125618
|View full text |Cite
|
Sign up to set email alerts
|

Brucine PEGylated nanoemulsion: In vitro and in vivo evaluation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
20
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 29 publications
(21 citation statements)
references
References 46 publications
1
20
0
Order By: Relevance
“…In fact, the results were in a proper range that could permit intravenous administration as formerly declared by Araújo et al, who estimated that it is reasonable for intravenous administration if the viscosity is lower than 3.9 cP [ 36 ]. These outcomes were in accordance with Elsewedy et al, who assessed the viscosity of Brucine NE to be up to 3.21 cP and established that it could safely be administered via intravenous route [ 37 ]. Further, Harun et al, estimated the viscosity of cefuroxime NE to be 1.24 cP and stated that it is acceptable for parenteral delivery as it is below 3.9 cP [ 38 ].…”
Section: Resultssupporting
confidence: 84%
See 1 more Smart Citation
“…In fact, the results were in a proper range that could permit intravenous administration as formerly declared by Araújo et al, who estimated that it is reasonable for intravenous administration if the viscosity is lower than 3.9 cP [ 36 ]. These outcomes were in accordance with Elsewedy et al, who assessed the viscosity of Brucine NE to be up to 3.21 cP and established that it could safely be administered via intravenous route [ 37 ]. Further, Harun et al, estimated the viscosity of cefuroxime NE to be 1.24 cP and stated that it is acceptable for parenteral delivery as it is below 3.9 cP [ 38 ].…”
Section: Resultssupporting
confidence: 84%
“…The supernatant was diluted with PBS 7.4 and analyzed for their absorbance at λmax 550 nm. For control, erythrocytes were incubated only with PBS or mixing with 1 mL of Triton-X 100 (1%) to attain 100% hemoglobin release [ 37 ].…”
Section: Methodsmentioning
confidence: 99%
“…A Brookfield viscometer (DV-II + Pro, USA) was employed to determine the viscosity of the formulated gel, emulgel and nanoemulgel using a spindle R5 rotated at 0.5 rpm at 25 ± 0.3 °C [ 19 ].…”
Section: Methodsmentioning
confidence: 99%
“…Samples were measured spectrophotometrically at different time intervals (0.25, 0.5, 1, 2 until 6 h) at λ max 425 nm. Each experiment was performed in triplicate [ 19 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation