2019 93rd ARFTG Microwave Measurement Conference (ARFTG) 2019
DOI: 10.1109/arftg.2019.8739180
|View full text |Cite
|
Sign up to set email alerts
|

Calibrated Digital Predistortion Using a Vector Network Analyzer as the Receiver

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…Figure 10 shows the measurement system developed in [26,27], which aims to capture both static and dynamic behavior of the two amplifiers in a transmitter based on Doherty or Cheirex principles, as well as the behavior of the whole transmitter. In this system, the modulated baseband signals used to drive the inputs of the amplifiers are upconverted to RF frequency using a dual-channel AWG (Keysight M8190A).…”
Section: Large-signal Characterization Using Modulated Signalsmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 10 shows the measurement system developed in [26,27], which aims to capture both static and dynamic behavior of the two amplifiers in a transmitter based on Doherty or Cheirex principles, as well as the behavior of the whole transmitter. In this system, the modulated baseband signals used to drive the inputs of the amplifiers are upconverted to RF frequency using a dual-channel AWG (Keysight M8190A).…”
Section: Large-signal Characterization Using Modulated Signalsmentioning
confidence: 99%
“…In order to accurately characterize dual-input devices using the testbed shown in Figure 10, the system has to be calibrated using the procedure introduced in [26,27]. Since the system comprises three ports (two inputs and one output), three-port relative calibration along with absolute power calibration are required.…”
Section: Calibration Of the Measurement Systemmentioning
confidence: 99%
“…While the inherent narrow IF BW of VNAs is typically insufficient for modern modulation BWs, techniques for measuring parts of the signal separately and then stitch them together with preserved phase and amplitude for the full-BW response have also been proposed [21]. These systems can make use of the built-in calibration features of the VNA system but need workarounds to handle the wide BW and to overcome the limited access to the internal hardware for timing and triggering [24].…”
mentioning
confidence: 99%