2020
DOI: 10.1007/s00604-020-4124-z
|View full text |Cite
|
Sign up to set email alerts
|

Cathodic electrodeposited Cu-BTC MOFs assembled from Cu(II) and trimesic acid for electrochemical determination of bisphenol A

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 44 publications
1
18
0
Order By: Relevance
“…Moreover, the peak currents increased, and the peak potentials shifted negatively, indicating that Cu-TCPP showed a high catalytic ability toward the oxidation of HQ and CC. As previously reported, Cu 2+ can be seen as the catalytic activity center [32,33]. In conclusion, the Cu-TCPP nanosheets can be used as sensitization material for the simultaneous…”
Section: Enhanced Oxidation Of Hq and CC On Cu-tcpp/gcesupporting
confidence: 74%
“…Moreover, the peak currents increased, and the peak potentials shifted negatively, indicating that Cu-TCPP showed a high catalytic ability toward the oxidation of HQ and CC. As previously reported, Cu 2+ can be seen as the catalytic activity center [32,33]. In conclusion, the Cu-TCPP nanosheets can be used as sensitization material for the simultaneous…”
Section: Enhanced Oxidation Of Hq and CC On Cu-tcpp/gcesupporting
confidence: 74%
“…To validate the electrode process, the plot of the peak current versus square roots of scanning rate was drawn, and the resulting plot was a straight line with satisfactory linearity in the interval from 25 to 500 mV/s as presented in Figure 11 with the correlation coefficient (R 2 ) of 0.9978. These results indicate that the electrode process is diffusion-controlled (28,43).…”
Section: Influence Of Potential Scan Rate On Response Oxidation Peak Current Of Bpamentioning
confidence: 68%
“…The influence of changing the employed scan rate for 100 µM BPA in PBS pH 4.0 was examined by the CV technique at the PGA/PGE as demonstrated in Figure 10. The experiment findings acquired from the PGA/PGE displayed a rise in the peak currents with higher applied scanning rate, and they were proportional to each other based on the Randles-Sevcik equation (43). The finding suggested that there was a shift of the oxidation peak potential towards the less negative side.…”
Section: Influence Of Potential Scan Rate On Response Oxidation Peak Current Of Bpamentioning
confidence: 80%
“…Hu et al. deposited Cu‐BTC films on the surface of glassy carbon electrode (GCE) via CDS with trimesic acid (H 3 BTC) as ligands and copper nitrates as metal sources and constructed an electrochemical platform for the determination of bisphenol A by taking advantages of the electrocatalytic activity of copper ions [73] . Similarly, Su et al.…”
Section: Electrochemical Synthesis Methods Of Mofsmentioning
confidence: 99%