2018
DOI: 10.1002/etep.2674
|View full text |Cite
|
Sign up to set email alerts
|

Centralized coordination of load shedding and protection system of transmission lines

Abstract: Summary The power system integrity is vulnerable to thermal limit of transmission lines due to overloading and consequently activation of their protection devices following severe contingencies. In this paper, the loading rate of transmission lines is monitored online and is considered in the centralized load shedding to concentrate the control action on loads causing line loading rate violation to prevent cascading failure of lines. To this aim, the loads are ranked based on a criterion called Outage Sensitiv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 10 publications
0
6
0
Order By: Relevance
“…OSI proposed in 32 is further used to design a load shedding scheme based on the voltage magnitude as well as transmission line loading in Reference 33. A load shedding index (LSI) is included in OSI.…”
Section: Methods Used In Sips Implementationmentioning
confidence: 99%
See 1 more Smart Citation
“…OSI proposed in 32 is further used to design a load shedding scheme based on the voltage magnitude as well as transmission line loading in Reference 33. A load shedding index (LSI) is included in OSI.…”
Section: Methods Used In Sips Implementationmentioning
confidence: 99%
“…In Reference 38, a PMU based load shedding strategy is proposed that includes the wind generation. The amount of load shedding is proposed by the Equation (33).…”
Section: Load Shedding Strategy In Wind Generation Scenariomentioning
confidence: 99%
“…The first solution is load shedding at the receiving end bus. This countermeasure is elaborated in details in [1,3], but it is out of scope of this paper. The second alternative is reducing the generation in the sending end bus, which is the main topic of this paper.…”
Section: Maximum Apparent Power Dispatch Of Wppmentioning
confidence: 99%
“…Cascading failures are a series of successive and dependent outages that progressively weaken the stability of power system leading to blackouts and thus significant economical losses [1]. Classification of recent major blackouts reveals that cascading failures due to overloading of power system components is the main initiating incident of blackouts after short-circuit fault followed by protection system malfunction and power plant outage.…”
Section: Introductionmentioning
confidence: 99%
“…The above‐mentioned damping methods are cost‐effective. However, satisfactory performance from these linear control approaches are achieved only within the predefined operating conditions; many nonlinear dynamics may be triggered for the wind speeds below 12 m/s . To overcome this shortcoming, a robust nonlinear damping control method is necessary.…”
Section: Introductionmentioning
confidence: 99%