1993
DOI: 10.1021/jf00035a048
|View full text |Cite
|
Sign up to set email alerts
|

Changes in the odorants of boiled trout (Salmo fario) as affected by the storage of the raw material

Abstract: Aroma extract dilution analysis of freshly harvested and boiled trouts (A) resulted in 24 odorants, of which 19 were identified. Twelve compounds were quantified by isotope dilution assays in sample A, in boiled trouts of which the raw material had been stored for 17 weeks a t -13 "C (B), and in homogenates which were freshly prepared and boiled (C) or stored for 14 weeks a t -13 "C and then boiled (D).Calculation of odor activity values (OAVs, ratio of concentration t o odor threshold) revealed (2)-1,5-octadi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
84
0
1

Year Published

1996
1996
2010
2010

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 109 publications
(88 citation statements)
references
References 24 publications
3
84
0
1
Order By: Relevance
“…1, 2 ((S) -( + ) -2-methylbutanal), 3-6, 16, 17, 23, 27, 29, 31, 36; no. 40 (3- (10), (Z) -2-nonenal (11), 6-acetyltetrahydropyridine (12), [ 2 H] -6-acetyltetrahydropyridine (13), (E,Z) -2, 4-decadienal (14) (21), [ 2 H]methylpropanal (9), [ [ 13 C 2 ]-4-Hydroxy-2, 5-dimethyl-3 (2H) -furanone was synthesized according to Sen et al (23) and then purified as follows: the reaction mixture (120 mg) containing the target compound and its acyclic precursor, in portions of 6 mg, was subjected to flash chromatography (24) on a column (36 ϫ 1.9 cm; Baker, Phillipsburg, U.S.A.) packed with Bakerbonddiol (40 µm, 10 g). After applying 2 mL of the reaction mixture, elution was performed with pentane/diethyl ether (1 + 1 by volume, 20 mL, fraction 1), pentane/ diethyl ether (3 + 7 by volume, 30 mL, fraction 2) and diethyl ether (100 mL, fraction 3).…”
Section: Chemicalsmentioning
confidence: 99%
“…1, 2 ((S) -( + ) -2-methylbutanal), 3-6, 16, 17, 23, 27, 29, 31, 36; no. 40 (3- (10), (Z) -2-nonenal (11), 6-acetyltetrahydropyridine (12), [ 2 H] -6-acetyltetrahydropyridine (13), (E,Z) -2, 4-decadienal (14) (21), [ 2 H]methylpropanal (9), [ [ 13 C 2 ]-4-Hydroxy-2, 5-dimethyl-3 (2H) -furanone was synthesized according to Sen et al (23) and then purified as follows: the reaction mixture (120 mg) containing the target compound and its acyclic precursor, in portions of 6 mg, was subjected to flash chromatography (24) on a column (36 ϫ 1.9 cm; Baker, Phillipsburg, U.S.A.) packed with Bakerbonddiol (40 µm, 10 g). After applying 2 mL of the reaction mixture, elution was performed with pentane/diethyl ether (1 + 1 by volume, 20 mL, fraction 1), pentane/ diethyl ether (3 + 7 by volume, 30 mL, fraction 2) and diethyl ether (100 mL, fraction 3).…”
Section: Chemicalsmentioning
confidence: 99%
“…Par ailleurs, certains composés volatils sont connus pour avoir de faibles seuils de perception et ils pourraient être très impliqués dans l'arôme caractéristique des dattes (la 2,3-pentanedione, par exemple, qui a un seuil de 5 µg·kg -1 dans l'eau [18]). De même, d'autres composés présents à des concentrations largement supérieures à leurs seuils de perception peuvent également être importants pour l'arôme des dattes.…”
Section: Resultsunclassified
“…This can be accomplished by steam distillation, high vacuum distillation, or DHS. Milo and Grosch [64] performed direct solvent extraction followed by high vacuum distillation for the isolation of volatiles from boiled trout, salmon, and cod. An alternative approach is to isolate the volatile components from the sample by distillation, followed by solvent extraction of the aqueous distillate [15,19].…”
Section: Direct Solvent Extractionmentioning
confidence: 99%
“…The value of CI-MS in flavour analysis is to complement and supplement the data provided by EI-MS [19]. CI-MS is commonly used in stable isotope dilution analysis and has been applied to the analysis of important seafood aroma compounds [36,64,102].…”
Section: Chemical Ionization Mass Spectrometrymentioning
confidence: 99%