Characteristics of a novel treatment system for linear accelerator–based stereotactic radiosurgery

Abstract: The purpose of this study is to characterize the dosimetric properties and accuracy of a novel treatment platform (Edge radiosurgery system) for localizing and treating patients with frameless, image‐guided stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). Initial measurements of various components of the system, such as a comprehensive assessment of the dosimetric properties of the flattening filter‐free (FFF) beams for both high definition (HD120) MLC and conical cone‐based treatment… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
47
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 39 publications
(48 citation statements)
references
References 47 publications
1
47
0
Order By: Relevance
“…1,[15][16][17][18][19][20] To characterize the accuracy of our system prior to ACO and CIB, we wanted to determine which portion of the RTDs seen at non-zero couch angles were due to couch walkout. 1,[15][16][17][18][19][20] To characterize the accuracy of our system prior to ACO and CIB, we wanted to determine which portion of the RTDs seen at non-zero couch angles were due to couch walkout.…”
Section: Methodsmentioning
confidence: 99%
“…1,[15][16][17][18][19][20] To characterize the accuracy of our system prior to ACO and CIB, we wanted to determine which portion of the RTDs seen at non-zero couch angles were due to couch walkout. 1,[15][16][17][18][19][20] To characterize the accuracy of our system prior to ACO and CIB, we wanted to determine which portion of the RTDs seen at non-zero couch angles were due to couch walkout.…”
Section: Methodsmentioning
confidence: 99%
“…[1,11,25]. However, the technical obstacles in developing an MR-guided radiosurgery system are significant due to the interactions between the magnetic field of an MRI system and the linear accelerator (Linac) system.…”
mentioning
confidence: 99%
“…Relative AIC values of the three ES formulae are computed based on some open field photon S cp measurements from the Varian dataset and the reference 10. In all cases, the WPM model performed the best, and Sterling the worst.…”
Section: Resultsmentioning
confidence: 99%
“…For S cp in the Varian dataset (method 2 above) and the published measurement data from a Varian TrueBeam Edge unit,10 the quality of an ES formula was visualized in the normalSnormalcp0.277778emnormalvs.0.277778emnormalES plot. The reason for this was that if an ES formula correctly identified the underlying relationship between a rectangular field and its corresponding ES measured in S cp , then all data points, no matter whether they were from square field measurements or rectangular field measurements, should fall onto the same curve in a plot of normalSnormalcp0.277778emnormalvs.0.277778emnormalES.…”
Section: Methodsmentioning
confidence: 99%