Clinical evaluation of a transmission detector system and comparison with a homogeneous 3D phantom dosimeter

Abstract: To evaluate the performances of the Dolphin system for pre-treatment verification (IBA Dosimetry, Schwarzenbruck, Germany) based on transmission measurements, employing a clinical perspective. Methods and materials: Fifty treatment plans were verified by Dolphin and Delta 4 detectors (Scandidos, Uppsala, Sweden) during the same session and subsequently by the Delta 4 itself. The attenuation factor of the transmission detector (required for on-line dosimetry) was evaluated by comparing Delta 4 measurements with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…Attenuation of 6 MV beams along the central axis for the various detectors they compared ranged from 1.0% to 7.2%, with ion-chamberbased devices typically having higher attenuation (ranging from 3.3% to 7.2%) and diode transmission devices typically having lower attenuation (~1%). Another available transmission detector not included in the comparison by Li et al [13] is the Dolphin detector (IBA Dosimetry, Schwarzenbuck, Germany) [18,20,21]. The Dolphin is a 2D array of 1513 plane-parallel ion chambers.…”
Section: Discussionmentioning
confidence: 99%
“…Attenuation of 6 MV beams along the central axis for the various detectors they compared ranged from 1.0% to 7.2%, with ion-chamberbased devices typically having higher attenuation (ranging from 3.3% to 7.2%) and diode transmission devices typically having lower attenuation (~1%). Another available transmission detector not included in the comparison by Li et al [13] is the Dolphin detector (IBA Dosimetry, Schwarzenbuck, Germany) [18,20,21]. The Dolphin is a 2D array of 1513 plane-parallel ion chambers.…”
Section: Discussionmentioning
confidence: 99%
“…Another one is the ArcCHECK‐3DVH system (Sun Nuclear Corporation, Melbourne, FL, USA). A strict commissioning of Dolphin‐Compass and ArcCHECK‐3DVH, including the validation of accuracy for array measurement, beam modeling, and dose reconstruction, was performed in advance according to the manufacturer's standards 36,37 …”
Section: Methodsmentioning
confidence: 99%
“…A strict commissioning of Dolphin-Compass and ArcCHECK-3DVH, including the validation of accuracy for array measurement, beam modeling, and dose reconstruction, was performed in advance according to the manufacturer's standards. 36,37 In addition to the general accepted GPRs and individual volume-based GIs, the DEs% and volumetric errors (VEs%) between the TPS and measurement reconstructed dose distribution were recorded and analyzed by the Compass and 3DVH programs, respectively. 17,38 For target coverage, D mean and D max (mean and maximum dose), D 2 and D 98 (D x : dose received by x% of the volume), and V 95 and V 100 (V x : volume irradiated by x% of the prescription dose) of the PTV were calculated and compared.…”
Section: Pretreatment Psqa Measurement and Data Collectionmentioning
confidence: 99%
“…Also, our dosimetry calculation was carried out according to AAPM’s TG-51 protocol [ 9 ]. The experiment data were obtained utilizing a cylindrical ionization chamber, type Scanditronix Wellhofer CC13 having an active volume of 0.13 cm 3 installed over a motorized guide in a resistance temperature detector of IBA Blue Phantom [ 10 ].…”
Section: Methodsmentioning
confidence: 99%