Clinical usefulness of free light chain concentration as a tumor marker in multiple myeloma

Abstract: Monoclonal immunoglobulin, as a marker for monoclonal gammopathy, is evaluated by protein electrophoresis (PEP) and immunofixation electrophoresis (IFE). However, PEP and IFE are not satisfactory in sensitivity, objectivity, and facility. Recently, a highly sensitive, automated immunoassay for measurement of free light chain (FLC) concentrations in serum and urine has been developed for the identification and monitoring of patients with monoclonal gammopathy. To explore the clinical usefulness of measurement o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
14
0
4

Year Published

2005
2005
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(21 citation statements)
references
References 12 publications
3
14
0
4
Order By: Relevance
“…The present study shows higher sensitivity when a cut-off threshold of 2.0 for the k/l ratio was used, compared to serum PE (96.6% vs. 86.4%) in detecting MM. This finding is in agreement with that of other studies (15,16). The sensitivity was 100% when both assays were used.…”
Section: Discussionsupporting
confidence: 83%
See 1 more Smart Citation
“…The present study shows higher sensitivity when a cut-off threshold of 2.0 for the k/l ratio was used, compared to serum PE (96.6% vs. 86.4%) in detecting MM. This finding is in agreement with that of other studies (15,16). The sensitivity was 100% when both assays were used.…”
Section: Discussionsupporting
confidence: 83%
“…Using a cut-off threshold of 2.0 for the FLC ratio, 100% PPV and 96.8% NPV was noted, enabling us to differentiate polyclonal gammopathy from MM. Similar findings have been reported by Kang et al (15). The present study shows higher sensitivity when a cut-off threshold of 2.0 for the k/l ratio was used, compared to serum PE (96.6% vs. 86.4%) in detecting MM.…”
Section: Discussionsupporting
confidence: 78%
“…1 Serum FLC immunoassays have a sensitivity of less than 1 mg/l. 4 The conclusion drawn from these studies and others 11,[23][24][25][26] is that for the purpose of screening for monoclonal proteins for all diagnoses except AL, the FLC can replace the 24 h urine IFE; however, once a diagnosis of monoclonal gammopathy is made, the 24 h protein IFE should be done. For AL screening, however, the urine IFE should still be done in addition to the serum tests including the serum FLC.…”
Section: Urine Flc Assaymentioning
confidence: 99%
“…Both patients and physicians are reluctant to do 24-h urine collections because of the inconvenience posed, but depending on the indication for the original monoclonal protein study of the blood, they could be missing at least 10-17% of cases with either AL amyloidosis or LCMM by doing serum IFE alone. 11,14 The ease of performing the FLC measurement could rectify this deficiency and lead to earlier diagnosis of these disorders.…”
Section: Urine Flc Assaymentioning
confidence: 99%
“…Serum FLC immunoassays have a sensitivity of less than 1 mg/L (4). The conclusion drawn from these studies and others (12)(13)(14)(15)(16) is that for the purpose of screening for monoclonal proteins for all diagnoses except AL, the FLC can replace the 24 hour urine IFE; yet, once a diagnosis of MG is made, the 24 hour protein IFE should be done. For AL screening, however, the urine IFE should still be done in addition to the serum tests including the serum FLC.…”
Section: Role Of the Serum Flc Assay In Diagnosismentioning
confidence: 99%