Collaborative determination of trace element mass fractions and isotope ratios in AQUA-1 drinking water certified reference material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 19 publications
3
8
0
Order By: Relevance
“…To ensure the accuracy of the analytical results, river water reference material SLRS-6 was included in each batch of samples. While the concentrations of methylated Ge species were below LOD, the value of iGe, 6.75 ± 0.17 ng L − 1 (average and standard deviation of nine analyses from different analysis days) compare well with the 6.87 ± 0.12 ng L − 1 iGe value obtained with the 'Ge-specific' setup (García-Figueroa et al, 2021) and also with the total Ge indicative value from a recent collaborative study on SLRS-6: 6.56 ± 0.32 ng L − 1 (Yeghicheyan et al, 2021).…”
Section: Analytical Considerationssupporting
confidence: 81%
“…To ensure the accuracy of the analytical results, river water reference material SLRS-6 was included in each batch of samples. While the concentrations of methylated Ge species were below LOD, the value of iGe, 6.75 ± 0.17 ng L − 1 (average and standard deviation of nine analyses from different analysis days) compare well with the 6.87 ± 0.12 ng L − 1 iGe value obtained with the 'Ge-specific' setup (García-Figueroa et al, 2021) and also with the total Ge indicative value from a recent collaborative study on SLRS-6: 6.56 ± 0.32 ng L − 1 (Yeghicheyan et al, 2021).…”
Section: Analytical Considerationssupporting
confidence: 81%
“…However, data from the recent publication of Yeghicheyan et al . (2021) for the determination of trace element concentrations in AQUA‐1 agrees with the values found in this study, with the exception of Ti, which was reported as indicative only in both studies. No literature values were provided for In and W.…”
Section: Resultssupporting
confidence: 90%
“…With the objective of assessing the possible matrix effects caused by other elements and chemical compounds present in the sample, a comparison of slopes obtained for external calibration in 0.2% (w/v) HNO 3 and standard addition was performed using CRMs SLRS-6 (river water) and CASS-6 (seawater) with known matrix composition and concentrations of potentially interfering elements. , The calibration interval was 5–15 ng L –1 of Te IV+VI ( n = 3), with a ratio of 1:1 for Te IV and Te VI . This comparison was performed with and without pre-reduction to confirm its suitability in real samples; thus, Te IV and Te IV+VI were compared.…”
Section: Resultsmentioning
confidence: 99%