2012
DOI: 10.1063/1.4733534
|View full text |Cite
|
Sign up to set email alerts
|

Commentary: JWST near-infrared detector degradation— finding the problem, fixing the problem, and moving forward

Abstract: The James Webb Space Telescope (JWST) is the successor to the Hubble Space Telescope. JWST will be an infrared-optimized telescope, with an approximately 6.5 m diameter primary mirror, that is located at the Sun-Earth L2 Lagrange point. Three of JWST’s four science instruments use Teledyne HgCdTe HAWAII-2RG (H2RG) near infrared detector arrays. During 2010, the JWST Project noticed that a few of its 5 μm cutoff H2RG detectors were degrading during room temperature storage, and NASA chartered a “Detector Degrad… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 32 publications
(12 citation statements)
references
References 8 publications
1
11
0
Order By: Relevance
“…The rate of bad-pixel formation in all three FPAs has been much slower since the observatory was launched and the FPAs were cooled to their operating temperatures. This experience is consistent with the experience of the James Webb Space Telescope (JWST) Detector Degradation Failure Review Board (Rauscher et al, 2012), which documented rapid degradation of this class of HgCdTe FPAs at room temperature and much slower degradation at cryogenic temperatures.…”
Section: Bad Pixels and Bad Samplessupporting
confidence: 73%
“…The rate of bad-pixel formation in all three FPAs has been much slower since the observatory was launched and the FPAs were cooled to their operating temperatures. This experience is consistent with the experience of the James Webb Space Telescope (JWST) Detector Degradation Failure Review Board (Rauscher et al, 2012), which documented rapid degradation of this class of HgCdTe FPAs at room temperature and much slower degradation at cryogenic temperatures.…”
Section: Bad Pixels and Bad Samplessupporting
confidence: 73%
“…The 2012 LWIR detector arrays delivered by TIS also benefited from process improvements that were made after detector degradation was noticed by the JWST program. 20 The failure mode has been identified by TIS and has been fully eliminated through process modifications. The improved approach has already been implemented in most Teledyne FPA products for several years, with no reports of similar failures.…”
Section: Prior Developmentmentioning
confidence: 99%
“…Testing of prototype units with the revised design indicates that the root cause has been addressed successfully and that the new detectors will be appropriately robust. 12 Replacement detector assemblies incorporating the new focal plane arrays are not expected to be available for installation into the NIR SI's until 2014.…”
Section: Overall Isim Iandt Flowmentioning
confidence: 99%