2017
DOI: 10.1007/s13246-017-0545-3
|View full text |Cite
|
Sign up to set email alerts
|

Commissioning a hobby cutting device for radiochromic film preparation

Abstract: In addition to a high spatial resolution and well characterised dose response, one of the major advantages of radiochromic film as a dosimeter is that sheets of film can be cut into pieces suitable for use as calibration films, and for in vivo and phantom measurements. The cutting of film is typically done using scissors or a guillotine, and this process can be time-consuming, limited in precision, requires extensive handling and does not allow holes to be cut from the film without cutting from an existing edg… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…This would be due to the curvature of the eyeball surface, which brings the treated tissue closer to the source than the applicator standoff distance, and is a more realistic approximate of what a patient would receive at this depth during a treatment. It would have been ideal to measure the dose at the surface of the eyeball phantom, but delamination is a common issue encountered in film dosimetry [12]. It is therefore advisable to use planar measurements (such as shown in Figure 2) for any routine quality assurance of the Sr-90 source, but as there is a difference between measurements performed on a flat set up and those done on an anthropomorphic phantom, the 3D printing of an eyeball phantom can help give a more realistic indication of the dose received by a patient undergoing this treatment.…”
Section: Discussionmentioning
confidence: 99%
“…This would be due to the curvature of the eyeball surface, which brings the treated tissue closer to the source than the applicator standoff distance, and is a more realistic approximate of what a patient would receive at this depth during a treatment. It would have been ideal to measure the dose at the surface of the eyeball phantom, but delamination is a common issue encountered in film dosimetry [12]. It is therefore advisable to use planar measurements (such as shown in Figure 2) for any routine quality assurance of the Sr-90 source, but as there is a difference between measurements performed on a flat set up and those done on an anthropomorphic phantom, the 3D printing of an eyeball phantom can help give a more realistic indication of the dose received by a patient undergoing this treatment.…”
Section: Discussionmentioning
confidence: 99%
“…The pieces of EBT3 film, of approximately 70 × 30 mm 2 , were cut following the curvature of the plaque, with the help of a paper template. Scissors were used, as it is reported to be a cutting method that minimizes film layer delamination, and care was taken to avoid brittle edges . All film pieces used in this work were irradiated at least 48 h after cutting, thus allowing relaxation of mechanical stress around the edges …”
Section: Methodsmentioning
confidence: 99%
“…With access to a laser cutter, the film-cutting process can be automated, allowing film to be cut with greater precision and reproducibility than with scissors [ 7 ]. The slow water penetration rate of Gafchromic films in general make it feasible to perform measurements directly in water [ 8 ].…”
Section: Introductionmentioning
confidence: 99%