2013
DOI: 10.1118/1.4790563
|View full text |Cite
|
Sign up to set email alerts
|

Commissioning of the Varian TrueBeam linear accelerator: A multi‐institutional study

Abstract: Overall, excellent agreement was observed in TrueBeam commissioning data. This set of multi-institutional data can provide comparison data to others embarking on TrueBeam commissioning, ultimately improving the safety and quality of beam commissioning.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

20
162
3
3

Year Published

2015
2015
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 156 publications
(188 citation statements)
references
References 29 publications
20
162
3
3
Order By: Relevance
“…Beam data from five TrueBeam linacs at three different institutions were previously compared, (9) and we noted excellent agreement between the beam data collected on the Edge and that on the TrueBeam linacs. The CC04 chamber was used to scan the PDDs and profiles for the Edge, while the CC 13 chamber was used for the TrueBeam, and due to its smaller active volume, dose falloff in profiles for the Edge was slightly sharper than that for the TrueBeam.…”
Section: Discussionsupporting
confidence: 60%
See 1 more Smart Citation
“…Beam data from five TrueBeam linacs at three different institutions were previously compared, (9) and we noted excellent agreement between the beam data collected on the Edge and that on the TrueBeam linacs. The CC04 chamber was used to scan the PDDs and profiles for the Edge, while the CC 13 chamber was used for the TrueBeam, and due to its smaller active volume, dose falloff in profiles for the Edge was slightly sharper than that for the TrueBeam.…”
Section: Discussionsupporting
confidence: 60%
“…The dedicated linacs have been designed exclusively for radiosurgery to further improve the targeting accuracy and high‐dose‐rate delivery. The mechanical isocenter accuracy of the C‐arm linac has reached submillimeter levels 8 , 9 . The flattening filter was first redesigned to be more efficient and later completely removed in order to deliver higher dose rates 10 , 11 .…”
Section: Introductionmentioning
confidence: 99%
“…The use of a 2%/2 mm gamma criteria and more rigorous small field testing was a good complement to the limited dataset recommended by vendors for commissioning. For users who wish to scrutinize their TPS models further, we recommend comparing your results to previous work on the topic of validation found in the literature 2, 3, 4, 5, 6, 7, 8, 9, 10, 11. Finally, we wanted to note what appears to be an error in MPPG 5.a to future users of the guideline.…”
Section: Discussionmentioning
confidence: 99%
“…In 2001, Venselaar et al6 proposed a set of tests and appropriate tolerances for photon beam dose calculations. In addition, validation tests for nonstandard treatment geometries, inhomogeneous media, MLC modeling, and commissioning have been described 7, 8, 9. The 2008 AAPM Task Group Report No.…”
Section: Introductionmentioning
confidence: 99%
“…These tests typically begin by measuring the accuracy of both static IMRT and RapidArc (Varian Medical Systems, Palo Alto, CA) treatments of simple spherical head tumors ranging from 3 cm to 1 cm in diameter with Gafchromic EBT3 film (Ashland Inc., Covington, KY). A different series of end‐to‐end tests were presented in a recent multi‐institutional study on the commissioning of a number of TrueBeam (Varian) linacs (7) . These tests typically focused on one type of dosimetric modality per phantom and not all phantoms were truly anthropomorphic.…”
Section: Introductionmentioning
confidence: 99%