2019
DOI: 10.1177/1753944719826335
|View full text |Cite
|
Sign up to set email alerts
|

Comparative preclinical evaluation of a polymer-free sirolimus-eluting stent in porcine coronary arteries

Abstract: Background:Polymer-free drug-eluting stents (DES) without permanent-polymer coating may be associated with rapid vessel healing, providing a rationale to reduce dual-antiplatelet therapy (DAPT). The aim of the current study was to compare vessel healing of a polymer-free sirolimus-eluting stent (PF-SES), its bare metal stent (BMS) analogue to a permanent polymer-based sirolimus-eluting stent (SES) with proven effectiveness in porcine coronary arteries.Material and methods:An ultrathin-strut cobalt–chromium PF-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
8
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 27 publications
2
8
1
Order By: Relevance
“…The PF-SES has a probucol-sirolimus coating on the abluminal side and was previously described by Krackhardt et al [8] PF-SES were implanted following each institution's guidelines and preferences. Preclinical data with this PF-SES and early optical coherence tomography data suggested rapid stent strut coverage [12].…”
Section: Methodsmentioning
confidence: 87%
“…The PF-SES has a probucol-sirolimus coating on the abluminal side and was previously described by Krackhardt et al [8] PF-SES were implanted following each institution's guidelines and preferences. Preclinical data with this PF-SES and early optical coherence tomography data suggested rapid stent strut coverage [12].…”
Section: Methodsmentioning
confidence: 87%
“…The method development and validation, as well as the pharmacokinetic studies, were conducted using pigs, since it has been used as an animal model to evaluate sirolimus-eluting stent in coronary arteries [ 36 ]. The validated bioanalytical method was used to determine the concentration of sirolimus in porcine whole blood and lung tissue following the application of stent devices containing sirolimus.…”
Section: Resultsmentioning
confidence: 99%
“…We did not observe higher ST rates in patients with renal impairment which may be due to the polymer-free stent surface and its more rapid stent strut coverage as observed in preclinical studies. [ 27 ]…”
Section: Discussionmentioning