2022
DOI: 10.1002/aws2.1293
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of coupon and pipe rack studies for selecting corrosion control treatment

Abstract: This study directly compared the data obtained from coupon studies and flow‐through pipe rack studies from two sources in the Denver Water system. The pipe rack study was completed over multiple years using harvested lead service lines. The coupon studies were completed in about 2 months using pure lead coupons. Orthophosphate at 2 mg/L was found to reduce lead concentrations by about 81% in the pipe racks, whereas 74%–81% was observed in the coupons. At an orthophosphate dose of 1 mg/L lead concentrations wer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(24 citation statements)
references
References 42 publications
0
24
0
Order By: Relevance
“…While most peer-reviewed literature focused on either bench top or pilot studies, Masters et al (2022) reported both coupon and pipe rack studies to examine the effects of pH adjustment and orthophosphate addition on lead leaching for two water sources in Denver, CO. Although the water chemistries were the same for both study types, the plumbing materials, stagnation time, sampling, and duration were different (Tables 2 and 5).…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…While most peer-reviewed literature focused on either bench top or pilot studies, Masters et al (2022) reported both coupon and pipe rack studies to examine the effects of pH adjustment and orthophosphate addition on lead leaching for two water sources in Denver, CO. Although the water chemistries were the same for both study types, the plumbing materials, stagnation time, sampling, and duration were different (Tables 2 and 5).…”
Section: Discussionmentioning
confidence: 99%
“…Use of a smaller water volume allowed for observation of minor changes in lead leaching, but limited the number of analyses that could be performed as a larger volume of water was needed to run certain analyses (Lytle et al, 1992). Some studies took composite samples at the end of each week (Bradley, 2018; CDPHE, 2019; Masters et al, 2022; Nguyen et al, 2010; Tang et al, 2018), which provided a greater volume of water to be analyzed and presumably simplified the study.…”
Section: Review Of Lead Corrosion Bench Top Studiesmentioning
confidence: 99%
See 3 more Smart Citations