Comparison of gamma (Anger) camera systems in terms of detective quantum efficiency using Monte Carlo simulation

Abstract: The results indicate that the manufacturers have succeeded differently in their attempts to design a system constituting an optimal compromise between sensitivity and spatial resolution.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 36 publications
(40 reference statements)
0
3
0
Order By: Relevance
“…In contrast, in this study, averaged PSF profiles are obtained after integration of line profiles passing through the center of the point image and covering various angles ranging from 0°to 180°with a 2°angle step. The FWHM as a measure of spatial resolution lacks the possibility for correct and complete system characterization, as different PSF shapes may show equal FWHM values [12].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In contrast, in this study, averaged PSF profiles are obtained after integration of line profiles passing through the center of the point image and covering various angles ranging from 0°to 180°with a 2°angle step. The FWHM as a measure of spatial resolution lacks the possibility for correct and complete system characterization, as different PSF shapes may show equal FWHM values [12].…”
Section: Discussionmentioning
confidence: 99%
“…To evaluate the performance of PET scanners, the PSF in a slice profile has traditionally been used [10,11]. The full width at half maximum (FWHM) of this function, which is used to measure the spatial resolution, lacks the possibility for complete system characterization and needs to be improved, as different PSF shapes may show equal FWHM values [12]. The response of the system to the incident signal amplitudes can be described by the MTF, which expresses the system's response in the spatial frequency domain by taking the Fourier transform of the corresponding PSF from a reconstructed cross-sectional image.…”
Section: Introductionmentioning
confidence: 99%
“…Emitted gamma rays should be deposited in the silicon detector in order to find the response of the detector. So we need to construct the geometry in such a way that gamma rays are absorbed in the silicon detector [6,7]. So we are placing an aluminum foil before the silicon detector.…”
Section: Figure 1: Digital Radiography Systemmentioning