2019
DOI: 10.1007/s10877-019-00310-2
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of LM-Supreme™ and endotracheal tube in patients undergoing gynecological laparoscopic surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 30 publications
0
6
0
1
Order By: Relevance
“…A previous study reported that the Baska mask demonstrated a level of utility comparable to that of SAD. Many studies have also been conducted to evaluate the effectiveness of the Baska mask compared to other airway devices [ 7 9 , 17 24 ]. In most studies, the Baska mask was considered an appropriate SAD for maintaining stable hemodynamics, effective tidal volume, and suitable airway pressures.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…A previous study reported that the Baska mask demonstrated a level of utility comparable to that of SAD. Many studies have also been conducted to evaluate the effectiveness of the Baska mask compared to other airway devices [ 7 9 , 17 24 ]. In most studies, the Baska mask was considered an appropriate SAD for maintaining stable hemodynamics, effective tidal volume, and suitable airway pressures.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, the peak airway pressure was significantly lower immediately after device insertion and 10 min after pneumoperitoneum in the Baska mask group. This is not surprising, because in general, a higher peak airway pressure is detected with the use of ET than with SADs [ 7 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Kuvaki et al [7] had observed that the 1 st h POST, dysphonia, and dysphagia were significantly higher following endotracheal intubation as compared to the use of LM-Supreme™. However, conflicting results were obtained with the use of ProSeal laryngeal mask versus endotracheal tubes.…”
Section: Discussionmentioning
confidence: 99%
“…Таким образом, имеющиеся литературные данные показывают, что ЛМ 2-го поколения являются надежными средствами поддержания проходимости ВДП, обеспечивающими высокую герметичность маска/ гортань при регургитации желудочного содержимого через дренажный канал. При строгом соблюдении всех условий использования ЛМ 2-го поколения респираторные риски анестезии близки к нулю [8]. Наличие дренажного канала и возможность опорожнять желудок от газа и жидкости в начале анестезии сделали ЛМ 2-го поколения реальной альтернативой ЭТТ в абдоминальной лапароскопической хирургии, гинекологии, урологии, при длительных ортопедических вмешательствах, при вмешательствах в положении пациента на животе и при плановой операции кесарева сечения [9][10][11][12][13][14].…”
Section: вентиляционная безопасность использования ларингеальной маск...unclassified