Comparison of self-expanding and balloon-expandable stents for the reduction of restenosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
22
1
4

Year Published

2002
2002
2013
2013

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(28 citation statements)
references
References 5 publications
1
22
1
4
Order By: Relevance
“…In native coronary arteries, nitinol self-expanding stents have a larger stent diameter compared with balloonexpandable stents on IVUS 6 months after stent implantation, although the benefit of continued radial expansion was somewhat balanced by increased intimal hyperplasia. 27 There is some possibility, however, that the mechanism is different between previous studies and the present study because the type of stent used in the current study was different from that in previous studies. Further prospective serial IVUS studies are required to reconfirm the result.…”
Section: Discussioncontrasting
confidence: 63%
“…In native coronary arteries, nitinol self-expanding stents have a larger stent diameter compared with balloonexpandable stents on IVUS 6 months after stent implantation, although the benefit of continued radial expansion was somewhat balanced by increased intimal hyperplasia. 27 There is some possibility, however, that the mechanism is different between previous studies and the present study because the type of stent used in the current study was different from that in previous studies. Further prospective serial IVUS studies are required to reconfirm the result.…”
Section: Discussioncontrasting
confidence: 63%
“…de reestenose após o implante de stents não-farmacológicos 7,8 . Além disso, alguns estudos têm sugerido que stents auto-expansíveis de nitinol podem produzir menos injúria à parede do vaso e promover maiores diâmetros luminais no seguimento angiográfico tardio 9,15 .…”
Section: Discussionunclassified
“…Han et al 9 demonstraram que stents auto-expansíveis em comparação com stents balão-expansíveis apresentaram resultados angiográficos similares entre os dois grupos aos seis meses de seguimento (perda tardia de 0,98 ± 0,62 mm vs. 0,94 ± 0,59 mm; p = 0,59). Aos nove meses, os resultados clínicos também foram similares (combinação de morte, infarto e nova revascularização): 19,3% vs. 20,1%.…”
Section: Discussionunclassified
See 1 more Smart Citation
“…There have been some reports that patients with lower pressure after stent implantation had less restenosis, presumably due to less barotrauma and subsequent intimal hyperplasia (8). These previous studies indicated that there is less restenosis in patients treated with lower pressures, suggesting that a prospective evaluation of the influence of inflation pressure on restenosis is warranted (8). As shown in Table 2, Radius stents were postdilated with low-moderate pressure (< 12 atm) and moderate-high pressure (12 to 16 atm).…”
Section: Discussionmentioning
confidence: 99%