2004
DOI: 10.1111/j.1532-849x.2004.04014.x
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of the Dimensional Accuracy of Injection‐Molded Denture Base Materials to that of Conventional Pressure‐Pack Acrylic Resin

Abstract: Processing the denture base materials produced unequal deformation in different dimensions (anterior-posterior and cross-arch). Each material tested also responded differently to the processing stages.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

7
137
0
7

Year Published

2005
2005
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 139 publications
(151 citation statements)
references
References 12 publications
7
137
0
7
Order By: Relevance
“…Another problem faced with the material was that no repair or relining is feasible.The flexible dentures were found kind to underlying soft tissues. There was no denture sore-mouth and the better comfort level was attributable to low modulus of elasticity [12,16]. Being a subjective analysis few patients were not able to comment on comfort level, phonetics etc and the same has not been included in the result.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Another problem faced with the material was that no repair or relining is feasible.The flexible dentures were found kind to underlying soft tissues. There was no denture sore-mouth and the better comfort level was attributable to low modulus of elasticity [12,16]. Being a subjective analysis few patients were not able to comment on comfort level, phonetics etc and the same has not been included in the result.…”
Section: Discussionmentioning
confidence: 99%
“…Since we provided flexible maxillary dentures, the present study can be considered as a case control study. Parvizi et al [16] compared the dimensional accuracy between injection molded dentures base material versus poly methyl methacrylate. They were of opinion that injection moulded dentures base material is superior in accuracy.…”
Section: Discussionmentioning
confidence: 99%
“…This material is very flexible so restoration can move with constant and easy installation in the mouth. This material is also extremely biocompatible (Negrutiu 2005, Phoenix 2004, Keenan, 2003, Parvizi 2004. …”
Section: Wide Base Removable Partial Denturesmentioning
confidence: 99%
“…1 Material ini mempunyai beberapa keunggulan antara lain estetik yang baik, kekuatan tinggi, menyerap air rendah, daya larut rendah, mudah dilakukan reparasi, proses manipulasi mudah karena tidak memerlukan peralatan rumit. 2 Oleh karena itu resin akrilik masih menjadi pilihan utama dokter gigi sebagai pembuatan basis gigi tiruan lepasan, meskipun saat ini telah banyak digunakan material logam campur sebagai basis gigi tiruan lepasan.…”
unclassified
“…8 Kekurangan material resin akrilik adalah bersifat toksik. 2 Metode kultur sel sering digunakan untuk pengujian efek biologi pada tingkat awal dari suatu material yang digunakan pada kedokteran gigi untuk mengetahui efek toksisitas. 8,9 Sel fibroblast BHK-21 adalah sel yang paling banyak digunakan para peneliti untuk uji toksisitas material di bidang kedokteran gigi.…”
unclassified