1992
DOI: 10.1080/00387019208020694
|View full text |Cite
|
Sign up to set email alerts
|

Complete1H and13C NMR Chemical Shift Assignments for Some Pentacyclic Oxindole Alkaloids

Abstract: Absaact:The complete analysis of the l H and 13C N M R has been performed for four pentacyclic oxindole alkaloids: mitraphylline, isomitraphylline, speciophylline and pteropodine. The total assignment of the l H N M R parameters was achieved from combined evaluation of homonuclear shift correlation and J-resolved diagrams, while DEPT spectra and selective decoupling experiments provided all carbon chemical shifts.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
6
0

Year Published

1996
1996
2013
2013

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 8 publications
2
6
0
Order By: Relevance
“…Tetramethylsilane was employed as the internal reference. The NMR spectral data were in full agreement with those described in the literature (29)(30)(31). On the other hand, pteropodine (isolated from U. tomentosa, g85%), ajmalicine hydrochloride (Fluka, g98%), and tryptamine (Sigma, 99+%) were used as the standard compounds to determine the calibration curves for MOA, MIA, and tryptamine alkaloids (TA), respectively.…”
Section: Alkaloid Standard Compounds and Calibrationsupporting
confidence: 82%
See 1 more Smart Citation
“…Tetramethylsilane was employed as the internal reference. The NMR spectral data were in full agreement with those described in the literature (29)(30)(31). On the other hand, pteropodine (isolated from U. tomentosa, g85%), ajmalicine hydrochloride (Fluka, g98%), and tryptamine (Sigma, 99+%) were used as the standard compounds to determine the calibration curves for MOA, MIA, and tryptamine alkaloids (TA), respectively.…”
Section: Alkaloid Standard Compounds and Calibrationsupporting
confidence: 82%
“…However, characterization and quantification of alkaloids produced by U. tomentosa cell cultures require obtaining reference substances, some of which are noncommercial materials, as well as developing analytical methodologies suitable for very small amounts of the alkaloids. The standard substances for the three major pentacyclic MOA produced by U. tomentosa;pteropodine (1), isopteropodine (2), and mitraphylline (3) (Figure 1);were isolated from commercial stem bark of this species and their identities were confirmed by 1 H NMR in comparison with the published spectral data (29)(30)(31). HPLC analysis of the stem bark extract of U. tomentosa obtained in the present work is shown in Figure 3a.…”
Section: Analysis Of Oxindole Alkaloids In U Tomentosasupporting
confidence: 68%
“…In order to optimise the extraction method and HPLC conditions for the determination of these alkaloids, a preliminary HPLC-UV analysis was carried out on a fraction obtained by liquid-liquid extraction of a commercial extract. The same alkaloid fraction was also used in a semi-preparative HPLC step to isolate pure standards of the alkaloids for later quantitative analyses: such compounds were identified by 1 H-NMR by comparison with data reported in literature (Toure et al, 1992;Seki et al, 1993).…”
Section: Hplc-es/ms Analyses Of Alkaloidsmentioning
confidence: 99%
“…Potassium dihydrogen phosphate was purchased from Merck (Germany) and Polyamide 6 from Macherey-Nagel (Germany). Mitraphylline was isolated and purified by column chromatography on silica-gel (Shellard et al, 1967); ppectrometric analysis data (MS, 1 H-and 13 C-NMR) were compatible with its structure and literature data (Toure et al, 1992).…”
Section: Chemicalsmentioning
confidence: 94%
“…Detection and quantitation limits (LOD and LOQ respectively) were calculated according to the equations LOD = 3.3σ/S and (0), cubic (−1, 1), axial (−α, α); n = 5 at the centre. (Toure et al, 1992). Appropriate dilutions were then prepared and analysed in order to confirm those limits.…”
Section: Detection and Quantitation Limitsmentioning
confidence: 99%