2020
DOI: 10.1371/journal.pone.0232638
|View full text |Cite
|
Sign up to set email alerts
|

Consensus based SoC trajectory tracking control design for economic-dispatched distributed battery energy storage system

Abstract: The state-of-charge (SoC) of an energy storage system (ESS) should be kept in a certain safe range for ensuring its state-of-health (SoH) as well as higher efficiency. This procedure maximizes the power capacity of the ESSs all the times. Furthermore, economic load dispatch (ELD) is implemented to allocate power among various ESSs, with the aim of fully meeting the load demand and reducing the total operating cost. In this research article, a distributed multi-agent consensus based control algorithm is propose… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 19 publications
(23 citation statements)
references
References 26 publications
(51 reference statements)
0
23
0
Order By: Relevance
“…As depicted in Figs. 22-24, the control scheme presented in [31]- [33] exhibits a slower convergence and larger deviations in case of equal active power sharing, than the proposed control scheme depicted in Figs. 11,16, and 20 under the same conditions.…”
Section: Case 5: Comparison Of the Proposed Secondary Control Scheme mentioning
confidence: 86%
See 3 more Smart Citations
“…As depicted in Figs. 22-24, the control scheme presented in [31]- [33] exhibits a slower convergence and larger deviations in case of equal active power sharing, than the proposed control scheme depicted in Figs. 11,16, and 20 under the same conditions.…”
Section: Case 5: Comparison Of the Proposed Secondary Control Scheme mentioning
confidence: 86%
“…24, the scheme presented in [31]- [33], exhibits larger oscillations in power sharing under large time-delays (i.e., 500 ms), than the proposed control scheme depicted in Fig. 20, and the consensus/convergence is not achieved even after t = 10 s. Similarly, in case of frequency regulation, the scheme presented in [31]- [33], exhibits much larger deviations, as depicted in Figs. 25-27 than the proposed scheme depicted in Figs.…”
Section: Case 5: Comparison Of the Proposed Secondary Control Scheme mentioning
confidence: 87%
See 2 more Smart Citations
“…Multiple VSMs can also be implemented to improve the performance of MHPPs in the presence of damping, inertia, power, and voltage loops. Some robust techniques like adaptive fuzzy [117] control and battery energy storage system with consensus [118] can be incorporated with synthetic inertia emulation techniques. The effect of power converters and its overloading capability in the context of VSM based MHPP can also be explored for further research work.…”
Section: Discussionmentioning
confidence: 99%