2015
DOI: 10.1016/j.ijheatmasstransfer.2015.01.077
|View full text |Cite
|
Sign up to set email alerts
|

Coupled inviscid-viscous solution method for bounded domains: Application to data-center thermal management

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(2 citation statements)
references
References 33 publications
0
2
0
Order By: Relevance
“…The air velocity in base room is small, and the airflow is regarded as turbulence whose thermal properties are constant [35][36][37]. The k-ε model has the advantages of short calculation time, high stability, and reasonable prediction of large-scale turbulence; thus, it has been widely used in the simulation of airflow distribution in DCs [26,36,38,39]. Since the internal environment of base room is relatively closed and the internal air flow is large space flow, it is suitable for the model of high Reynolds number turbulence calculation [40,41].…”
Section: Control Equation and Turbulence Modelmentioning
confidence: 99%
“…The air velocity in base room is small, and the airflow is regarded as turbulence whose thermal properties are constant [35][36][37]. The k-ε model has the advantages of short calculation time, high stability, and reasonable prediction of large-scale turbulence; thus, it has been widely used in the simulation of airflow distribution in DCs [26,36,38,39]. Since the internal environment of base room is relatively closed and the internal air flow is large space flow, it is suitable for the model of high Reynolds number turbulence calculation [40,41].…”
Section: Control Equation and Turbulence Modelmentioning
confidence: 99%
“…However, the standard k-turbulent is a currently widely used and accepted turbulent model used in the DC numerical simulations (Yuan et al, 2018), while its reliability and feasibility have been validated in many studies (Alkharabsheh et al, 2015;Cruz & Joshi, 2015;Ham & Jeong, 2016;Phan & Lin, 2014;Song, 2016). Some assumptions were taken into consideration in the simulation process with the standard k-model: (i) the ignorance of radiation effects, (ii) no air leakage, (iii) the air was regarded as an incompressible fluid, and the flow was considered to be steady turbulent flow, and (iv) the temperature of air flow supplied from all the tiles were the same.…”
Section: Governing Equationmentioning
confidence: 99%