2017
DOI: 10.1186/s12955-017-0785-7
|View full text |Cite
|
Sign up to set email alerts
|

Cross-cultural validation of simplified Chinese version of spine functional index

Abstract: BackgroundNo effective constructs were available in mainland China to assess the whole spine function. The SFI was developed to evaluate spinal function based on the concept of a single kinetic chain concept for whole spine. The SFI has been translated to Spanish and Turkish with accepted psychometric properties. It is imperative to introduce the SFI in mainland China and further to explore the measurement properties.MethodsThe English versions of the SFI was cross-culturally translated according to internatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
17
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(20 citation statements)
references
References 30 publications
2
17
1
Order By: Relevance
“…It was shown that the SFI-Pr had very high test-retest reliability (ICC 2.1 = 0.96) that was identical to the Spanish and Chinese versions (ICC 2.1 = 0.96) [ 22 ], very close to the original English (ICC 2.1 = 0.97) [ 9 ], but higher than both the Turkish [ 6 ] and Korean [ 23 ] (ICC 2.1 = 0.93). Further, the internal consistency (α = 0.80) was lower than the four previously reported versions including the original (α = 0.91) [ 9 ], Chinese (α = 0.91) [ 40 ], Turkish and Korean (α = 0.85) [ 6 ] and Spanish (α = 0.84) [ 22 ] but above the required threshold [ 45 ] for acceptance.…”
Section: Discussionmentioning
confidence: 63%
See 4 more Smart Citations
“…It was shown that the SFI-Pr had very high test-retest reliability (ICC 2.1 = 0.96) that was identical to the Spanish and Chinese versions (ICC 2.1 = 0.96) [ 22 ], very close to the original English (ICC 2.1 = 0.97) [ 9 ], but higher than both the Turkish [ 6 ] and Korean [ 23 ] (ICC 2.1 = 0.93). Further, the internal consistency (α = 0.80) was lower than the four previously reported versions including the original (α = 0.91) [ 9 ], Chinese (α = 0.91) [ 40 ], Turkish and Korean (α = 0.85) [ 6 ] and Spanish (α = 0.84) [ 22 ] but above the required threshold [ 45 ] for acceptance.…”
Section: Discussionmentioning
confidence: 63%
“…The construct validity of the SFI questionnaire was tested with EFA. The single factor solution was found in all four previous analysis of the SFI [ 6 , 9 , 22 , 40 ], however it was suggested that as some factors were notably below the loading suppression cutoff of 0.30 some items could potentially be removed. Consequently, item redundancy may be present and a shortened tool should be considered [ 6 ].…”
Section: Discussionmentioning
confidence: 90%
See 3 more Smart Citations