1999
DOI: 10.1016/s0300-5712(99)00007-x
|View full text |Cite
|
Sign up to set email alerts
|

Dental materials: 1997 literature review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
24
0
5

Year Published

2002
2002
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 53 publications
(29 citation statements)
references
References 246 publications
0
24
0
5
Order By: Relevance
“…As a consequence of this study, two injections in CG-MS were proposed using two different injector temperatures: (1) 200 ~ for the determination of BPA and TEGDMA in order to avoid the interference due to the degradation products of bis-GMA and (2) 300 ~ for the determination of bis-GMA and bis-DMA. Figure 3 shows the mass spectra obtained in scan mode for these compounds.…”
Section: Gc-ms Analysis Of Bpa Bis-gma Bis-dma Andtegdmamentioning
confidence: 99%
See 1 more Smart Citation
“…As a consequence of this study, two injections in CG-MS were proposed using two different injector temperatures: (1) 200 ~ for the determination of BPA and TEGDMA in order to avoid the interference due to the degradation products of bis-GMA and (2) 300 ~ for the determination of bis-GMA and bis-DMA. Figure 3 shows the mass spectra obtained in scan mode for these compounds.…”
Section: Gc-ms Analysis Of Bpa Bis-gma Bis-dma Andtegdmamentioning
confidence: 99%
“…Dental resin systems based on dimethacrylate monomers like bisphenol-A diglycidyl dimethacrylate (bis-GMA) and bisphenol-A dimethacrylate (bis-DMA) are now used because they are an alternative to the dental amalgams [1 ]. bis-GMA is synthesised from bisphenol-A (BPA) and glycidyl methacrylates having appropriate mechanical properties, chemical stability and simulates natural tooth colour.…”
Section: Introductionmentioning
confidence: 99%
“…Biomaterials should not induce an abnormal host response or suffer degradation when exposed to body fluids. [2][3][4] These requirements are of extreme importance to a successful implantation.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, FCR is usually used as a liner in areas of difficult access or flow such as irregular internal surfaces and proximal boxes of Class II preparations. This is because FCR easily flows into, adapts to, and fills the tooth surface, resulting in less leakage and hence less internal restorations with voids and post-operative sensitivity [1][2][3][4][5][6][7] . However, in restorations prepared by sandwich technique, gaps still exist between the FCR liner and the hybrid composite filling material 8) .…”
Section: Introductionmentioning
confidence: 99%
“…Then, for the analysis of flexural strength data, Weibull distribution analysis has been recommended. This is because it is capable of allowing for skewed data and predicting values within and outside the data set 4,[14][15][16][17][18][19] . By measuring flexural strength, the flexural modulus and modulus of resilience are measured too.…”
Section: Introductionmentioning
confidence: 99%