2017
DOI: 10.1007/s00542-017-3563-x
|View full text |Cite
|
Sign up to set email alerts
|

Design and Flow Analysis of MEMS based Piezo-electric Micro Pump

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 39 publications
(15 citation statements)
references
References 24 publications
0
15
0
Order By: Relevance
“…With this design a high pumping rate of up to 100 µL min −1 was reported to be theoretically feasible. Going forward to recent years, a theoretical design and simulation of a single piezoelectric micropump composed by zirconate titanate (PZT)-5H material, quartz and PDMS was reported by Sateesh et al (2018). Although piezoelectric pumps offer fast response times and high forces, high voltage needs and special care must be taken into account when mounting PZT discs.…”
Section: Mechanical Micropumpsmentioning
confidence: 99%
“…With this design a high pumping rate of up to 100 µL min −1 was reported to be theoretically feasible. Going forward to recent years, a theoretical design and simulation of a single piezoelectric micropump composed by zirconate titanate (PZT)-5H material, quartz and PDMS was reported by Sateesh et al (2018). Although piezoelectric pumps offer fast response times and high forces, high voltage needs and special care must be taken into account when mounting PZT discs.…”
Section: Mechanical Micropumpsmentioning
confidence: 99%
“…In the preceding sections the effect of channel angles has been elucidated; in parallel it is crucial to calculate the number of pipes in the proposed design to achieve maximum reabsorption rate. In Figure 2C at position 1, applying the Bernoulli principle, the total energy of fluid at the opening of the proximal tubule is given by LHS part of Equation (12) and the total energy of fluid at the orifice of first pipe is given by RHS part of Equation (12). Now let us assume P 1 -P 2 = ph; p = ΔP/Δx = Pressure Differential; to find vʹ, we have to transport some parts of the equation from RHS to LHS Upon solving where h is the distance between the orifice of pipe and opening of proximal tube pipes and h F is the friction head loss.…”
Section: Channels Needed For the Designmentioning
confidence: 99%
“…The Organ-on-a-Chip concept is an emerging and promising technology in recent times, which showcases the developments toward early stage detection of diseases and malfunctioning of the human body. [11][12][13] Most of the researchers and scientists have already started concentrating to resolve the issues by replicating the major functions of the organs on a chip. However, mimicking human kidney function is found to be more difficult than other functions in many other organs.…”
mentioning
confidence: 99%
“…Revathi and Padmanabhan designed a valveless micropump with a composite piezoelectric actuator which showed the maximum outflow at an aspect ratio of 15 for a nozzle/diffuser [10]. Sateesh et al [11] designed and modelled a piezoelectrically actuated micropump with PZT-5h and Polydimethylsiloxane (PDMS) with an outflow rate of 0.029 μL s1.…”
Section: Introductionmentioning
confidence: 99%