2015
DOI: 10.2174/1874444301507010008
|View full text |Cite
|
Sign up to set email alerts
|

Design of Non-Contact Infra-Red Thermometer Based on the Sensor of MLX90614

Abstract: Liquid identification becomes more and more important in the safety inspection at the subway, airport, and railway. Non-contact liquid security identification is the best way, because it can avoid the contamination of the liquids and the injuries caused by some corrosive and toxic liquids. The paper designed the non-contact Infra-Red thermometer based on the sensor of MLX90614 and the most favored microprocessor STM32F107 for the non-contact liquid security identification system. Completed the hardware circuit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0
3

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(19 citation statements)
references
References 0 publications
0
16
0
3
Order By: Relevance
“…MLX90614 has a low noise amplifier, 17-bit ADC, and powerful DSP unit, thus achieving high accuracy and resolution of the thermometer. The thermometer comes factory calibrated with a digital bus output giving full access to the measured temperature in the complete temperature range(s) with a resolution of 0.02°C [12]. The user can configure the digital output to be pulse width modulation (PWM).…”
Section: Body Temperature Sensor (Mlx90614)mentioning
confidence: 99%
See 1 more Smart Citation
“…MLX90614 has a low noise amplifier, 17-bit ADC, and powerful DSP unit, thus achieving high accuracy and resolution of the thermometer. The thermometer comes factory calibrated with a digital bus output giving full access to the measured temperature in the complete temperature range(s) with a resolution of 0.02°C [12]. The user can configure the digital output to be pulse width modulation (PWM).…”
Section: Body Temperature Sensor (Mlx90614)mentioning
confidence: 99%
“…The user can configure the digital output to be pulse width modulation (PWM). As a standard, the 10-bit PWM is configured to continuously transmit the measured temperature in the range of -20 to 120°C, with an output resolution of 0.14°C [12]. This sensor needs a 4-wire connection.…”
Section: Body Temperature Sensor (Mlx90614)mentioning
confidence: 99%
“…Another research for MLX90614 was conducted by [8]. The research used MLX90614 with Arduino for the microcontroller and HC-SR04.…”
Section: A Elastic Wlanmentioning
confidence: 99%
“…The monitoring and measurement of ST can be performed with contact and contacless methods i.e utiliziation of arduino controller [16][17][18][19][20][21][22][23][24], a wireless sensor technology incorporating radio frequency technology (RFT) [25] and android application [26]. These developed measuring prototypes were not suitable to use on large scale applications due to the designing limitation.…”
Section: Emotional Statesmentioning
confidence: 99%