Details of human middle ear morphology based on micro‐CT imaging of phosphotungstic acid stained samples

Abstract: A multitude of morphological aspects of the human middle ear (ME) were studied qualitatively and/or quantitatively through the postprocessing and interpretation of micro-CT (micro X-ray computed tomography) data of six human temporal bones. The samples were scanned after phosphotungstic acid staining to enhance soft-tissue contrast. The influence of this staining on ME ossicle configuration was shown to be insignificant. Through postprocessing, the image data were converted into surface models, after which the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
51
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 61 publications
(58 citation statements)
references
References 60 publications
3
51
1
Order By: Relevance
“…In the unloaded state the distance between the articular surfaces for all four TBs was within the range of 25 to 280 µm which is comparable to recent investigations of De Greef et al (2015). Dirckx et al (2005) proposed that friction effects are important in the quasi-static regime, but viscoelasticity may be the remaining factor at acoustic frequencies.…”
Section: Diathroidal Jointssupporting
confidence: 87%
“…In the unloaded state the distance between the articular surfaces for all four TBs was within the range of 25 to 280 µm which is comparable to recent investigations of De Greef et al (2015). Dirckx et al (2005) proposed that friction effects are important in the quasi-static regime, but viscoelasticity may be the remaining factor at acoustic frequencies.…”
Section: Diathroidal Jointssupporting
confidence: 87%
“…Nevertheless, this is to the best of our knowledge the first description of human inner ear development integrating high resolution  μ CT 3D imaging and mineral density measurement with histomorphological analysis of undecalcified skeletal samples. We thus combined accurate 3D imaging (vs. histology sections that may be misaligned using manual reconstruction softwares) at ultra high resolution (higher than MRI 16 ) with the high spatial resolution of histology on specimens with preserved bone tissue characteristics (undecalcified). Moreover, we are here providing observational developmental data on a highly sensitive population, and these are of direct interest for the interpretation of clinical symptoms.…”
Section: Discussionmentioning
confidence: 99%
“…It is reasonable to assume that the same is true for anatomical details that could have a significant influence on the system's mechanics and transfer function (e.g. (De Greef et al, 2015)). 385 Some recent finite element models of the middle include a simplified geometry for the TMC (Aernouts et al, 2012;De Greef et al, 2014;Hoffstetter et al, 2010;Koike et al, 2002;Volandri et al, 2012;Yao et al, 2013).…”
Section: Accepted Manuscriptmentioning
confidence: 99%