2011
DOI: 10.1017/s0022215110002859
|View full text |Cite
|
Sign up to set email alerts
|

Detection of tympanic membrane movement using film patch with integrated strain gauge, assessed by optical coherence tomography: experimental study

Abstract: Attachment of the film patch with integrated strain gauge to the tympanic membrane was not ideal. Nevertheless, the strain gauge was able to precisely detect small pressure changes within the middle ear, in this experimental model.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 9 publications
0
7
0
1
Order By: Relevance
“…Eine Objektivierung der Funktion der Eustachischen Röhre mittels apparativer Untersuchungen gestaltet sich weiterhin schwierig [10]. Verfahren wie die Sonotubometrie [11], Tubenmanometrie nach Estève [1] mit dem Tubenscore [21] oder Langzeitmessungen mit Dehnungsstreifen auf dem Trommelfell [5] werden aktuell hinsichtlich ihrer Zuverlässigkeit untersucht. Derzeit gibt es keine grundsätzlichen in Leitlinien und Übersichtsarbeiten empfohlenen Diagnostikverfahren und keine klare Empfehlung zur objektiven Beurteilung der Funktion der Eustachischen Röhre [8,13,20].…”
Section: Hintergrundunclassified
“…Eine Objektivierung der Funktion der Eustachischen Röhre mittels apparativer Untersuchungen gestaltet sich weiterhin schwierig [10]. Verfahren wie die Sonotubometrie [11], Tubenmanometrie nach Estève [1] mit dem Tubenscore [21] oder Langzeitmessungen mit Dehnungsstreifen auf dem Trommelfell [5] werden aktuell hinsichtlich ihrer Zuverlässigkeit untersucht. Derzeit gibt es keine grundsätzlichen in Leitlinien und Übersichtsarbeiten empfohlenen Diagnostikverfahren und keine klare Empfehlung zur objektiven Beurteilung der Funktion der Eustachischen Röhre [8,13,20].…”
Section: Hintergrundunclassified
“…Optotensometry is being developed for this purpose by Zehlicke et al ., but has currently only been demonstrated to work in a laboratory model. Another approach trialled in a cadaver model has been to attach a film patch with integrated strain gauge to the tympanic membrane …”
Section: Resultsmentioning
confidence: 99%
“…Another approach trialled in a cadaver model has been to attach a film patch with integrated strain gauge to the tympanic membrane. 64…”
Section: Evolving Techniquesmentioning
confidence: 99%
“…The in vivo application of OCT at the middle ear is challenging due to the curved auditory canal, which complicates the optical access to the tympanic membrane. One approach is to perform OCT through ear microscopes 21 or ear specula 5,8,11,22 with a long working distance being comparable with the length of the ear canal of ∼3 cm. In this case, the field-of-view for OCT is limited to a few millimeters and is not sufficient for scanning the entire tympanic membrane.…”
Section: Introductionmentioning
confidence: 99%