2016
DOI: 10.1021/acs.analchem.6b01550
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Halogenated Flame Retardants Using Gas Chromatography with Atmospheric Pressure Chemical Ionization (APCI) and a High-Resolution Quadrupole Time-of-Flight Mass Spectrometer (HRqTOFMS)

Abstract: A method to determine halogenated flame retardants was developed that utilizes gas chromatography with atmospheric chemical ionization (APCI) high-resolution quadrupole time-of-flight mass spectrometry (HRqTOFMS). The new GC-APCI-HRqTOFMS method was used to determine the presence of 65 halogenated flame retardants (HFRs) in the United Sates National Institute of Standards and Technology (NIST) organic contaminants in house dust standard reference material (SRM). The accuracy of the measurements was compared to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
22
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 40 publications
(23 citation statements)
references
References 29 publications
1
22
0
Order By: Relevance
“…The interface and ion source were held at 300°C and 150°C, respectively. A background ion present in the source region ( m/z 212.0750) was used as an internal mass calibrant [ 44 ]. Mass accuracy was <2 ppm at m/z 359.8145 (PCB 155).…”
Section: Methodsmentioning
confidence: 99%
“…The interface and ion source were held at 300°C and 150°C, respectively. A background ion present in the source region ( m/z 212.0750) was used as an internal mass calibrant [ 44 ]. Mass accuracy was <2 ppm at m/z 359.8145 (PCB 155).…”
Section: Methodsmentioning
confidence: 99%
“…The gold standard for measuring trace levels (femtogram) of POPs including PCDD/Fs has traditionally been with a gas chromatograph coupled to a double focusing magnetic deflection (sector)-high resolution mass spectrometer (GC-HRMS). However, gas chromatography with atmospheric pressure chemical ionization and tandem mass spectrometry (GC-APCI-MS/MS) has recently been used successfully to match the performance of the sector instrument for the analysis of PCBs, and PCDD/Fs (García-Bermejo et al, 2015;Geng et al, 2016;Megson et al, 2016;Organtini et al, 2015a;Organtini et al, 2015b;Stubleski et al, 2018;van Bavel et al, 2015). Sample analyses was performed using GC-APCI-MS/MS.…”
Section: Instrumental Analysismentioning
confidence: 99%
“…However, this is the first reported use of a middle‐resolution TOF for dioxin analysis . Very low LODs for PBDEs ranging from 0.062 to 1.4 pg/μL using GC–EI‐QTOF and GC–HRTOF equipped with APCI were reported .…”
Section: Introductionmentioning
confidence: 91%