1995
DOI: 10.1002/jhrc.1240181102
|View full text |Cite
|
Sign up to set email alerts
|

Determination of polychlorinated biphenyls in human blood plasma by on‐line and off‐line liquid chromatography–gas chromatography

Abstract: SummaryA method for the determination of non-, mono-and di-ortho substituted polychlorinated biphenyls in human blood plasma is presented. The non-ortho CBs are isolated from the bulk of PCBs by HPLC on a dinitroanilino-propyl silica column and collected as a heart-cut fraction that is transferred on-line to GC-MS utilizing concurrent solvent evaporation technique. The on-line coupling serves to lower the limit of determination and to partly automate the sample clean-up. The di-and mono-ortho CBs are analyzed … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

1995
1995
2005
2005

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 22 publications
(2 reference statements)
0
4
0
Order By: Relevance
“…An NPLC-GC -ECD method has been applied for the determination of levomoprol [15] and an NPLC-GC-MS method for polychlorinated biphenyls [17]. The latter method enabled a selective determination of toxic non-ortho-chlorobiphenyls in the presence of less toxic PCBs at a pg/g level.…”
Section: Liquid Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…An NPLC-GC -ECD method has been applied for the determination of levomoprol [15] and an NPLC-GC-MS method for polychlorinated biphenyls [17]. The latter method enabled a selective determination of toxic non-ortho-chlorobiphenyls in the presence of less toxic PCBs at a pg/g level.…”
Section: Liquid Samplesmentioning
confidence: 99%
“…Yet, further advantages are the shortened time of analysis and better reliability and repeatability. For biological and pharmaceutical samples, both SPE and LC have been coupled on-line with GC [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19]. Also other on-line techniques, such as membrane extraction and on-line LLE, have been directly coupled with GC, but these methods are not covered in this review.…”
Section: Introductionmentioning
confidence: 99%
“…In this project, the non-ortho substituted PCB congeners are isolated by high performance liquid chromatography (HPLC) on a dinitroanilino-propyl silica (DNAP) column, where CB-77, CB-126 and CB-169 are eluted as one peakafterthe other CBs. WithrespecttoPCBs, thiscolumn has previously been applied only to standard solutions [9].…”
Section: Introductionmentioning
confidence: 99%
“…For the determination of compounds in complex matrices containing interferences, FID and ECD are not always suitable. Therefore complicated hyphenated techniques such as LC-GC-MS [8][9][10] and LC-GC-FTIR 11 have been developed.…”
mentioning
confidence: 99%