2001
DOI: 10.2116/analsci.17.555
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the Molecular Mass of New l-Fucose-Containing Glycosaminoglycan and Its Distribution by High-Performance Gel-Permeation Chromatography with Laser Light-Scattering Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 20 publications
0
7
0
Order By: Relevance
“…The average molecular weight of SCP-1 was estimated to be 15.63 kDa on the basis of calibration with standard d -series dextrans. M w / M n was used to determine the width of the molecular weight distribution, which represents the dispersibility and homogeneity of a polymer . As a result, the M w / M n for SCP-1 was 1.695 estimated by GPC software version B01.01 (Agilent, USA).…”
Section: Resultsmentioning
confidence: 99%
“…The average molecular weight of SCP-1 was estimated to be 15.63 kDa on the basis of calibration with standard d -series dextrans. M w / M n was used to determine the width of the molecular weight distribution, which represents the dispersibility and homogeneity of a polymer . As a result, the M w / M n for SCP-1 was 1.695 estimated by GPC software version B01.01 (Agilent, USA).…”
Section: Resultsmentioning
confidence: 99%
“…The molecular weight distribution ( M w / M n ) is used to measure the width of molecular weight distribution, which represents the homogeneity and dispersibility of the polymer. The distribution data indicates that the natural polysaccharides are homogeneous [23]. …”
Section: Resultsmentioning
confidence: 99%
“…The purity of preparation was assayed by high-performance gel permeation chromatography (HPGPC) using a Agilent technologies1200 series (Agilent Co., USA) apparatus with RID (G1362A) and DAD (G1315D) detectors, equipped with a Shodex OH-pak SB-804 HQ column (8 mm × 300 mm). Chromatographic conditions and procedures were performed according to the previous method [23]. …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The purity of preparation was assayed by high-performance gel permeation chromatography (HPGPC) using a Agilent technologies1200 series (Agilent Co., Santa Clara, CA, USA) apparatus with RID (G1362A) and DAD (G1315D) detectors, equipped with a Shodex OH-pak SB-804 HQ column (8 mm × 300 mm). Chromatographic conditions and procedures were performed according to the previous method [ 19 , 36 ].…”