1995
DOI: 10.1016/0378-4347(94)00542-d
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the renin inhibitor Ro 42-5892 in human plasma by automated pre-column derivatization, reversed-phase high-performance liquid chromatographic separation and electrochemical detection after post-column irradiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

1998
1998
2015
2015

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 18 publications
0
2
0
Order By: Relevance
“…43 As a reference method, the authors used the HPLC method employing reversed phase chromatography on a C 18 column and post-column irradiation using a BeamBoost® followed by coulometric oxidative electrochemical detection at +550 mV vs. a H2/H 0 electrode, obtaining in this case a quanti-cation limit on the level of 0.2 ng mL À1 . Another method for remikiren determination in blood serum was proposed by Leube and Fischer, 44 and analysis was conducted using the HPLC method with pre-column derivatization of the examined substance with 2,4-dinitrouorobenzene and electrochemical detection; Ro-4661/000 compound was used as a standard. The derivatization process was performed automatically using borate buffer (0.2 M, pH 8.0) and 2,4-dinitrouorobenzene.…”
Section: Remikirenmentioning
confidence: 99%
“…43 As a reference method, the authors used the HPLC method employing reversed phase chromatography on a C 18 column and post-column irradiation using a BeamBoost® followed by coulometric oxidative electrochemical detection at +550 mV vs. a H2/H 0 electrode, obtaining in this case a quanti-cation limit on the level of 0.2 ng mL À1 . Another method for remikiren determination in blood serum was proposed by Leube and Fischer, 44 and analysis was conducted using the HPLC method with pre-column derivatization of the examined substance with 2,4-dinitrouorobenzene and electrochemical detection; Ro-4661/000 compound was used as a standard. The derivatization process was performed automatically using borate buffer (0.2 M, pH 8.0) and 2,4-dinitrouorobenzene.…”
Section: Remikirenmentioning
confidence: 99%
“…The second method used was a specific h.p.l.c. method employing reversed phase chromatography on a C18 column and post-column irradiation using a Beam Boost® followed by coulometric oxidative electrochemical detection at +550 mV vs a H2/H' electrode [17]. The limit of quantification was 0.2 ng ml-'.…”
Section: Pharmacokinetics and -Dynamics Of Remikiren 549mentioning
confidence: 99%