2020
DOI: 10.1007/s00253-020-10997-y
|View full text |Cite
|
Sign up to set email alerts
|

Development of a double monoclonal antibody–based sandwich enzyme-linked immunosorbent assay for detecting canine distemper virus

Abstract: Canine distemper virus (CDV) infection causes mass mortality in diverse carnivore species. For effective virus surveillance, rapid and sensitive assays are needed to detect CDV in field samples. In this study, after BABL/c mice were immunized with recombinant CDV-fusion (F) protein, monoclonal antibodies (mAbs) against recombinant CDV-F protein (designated 1A5, 1A6, and 7D5) were produced using traditional hybridoma cell technology. Next, capture antibody (1A6, 800 ng/well) and horseradish peroxidase (HRP)–con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 32 publications
0
10
0
Order By: Relevance
“…On the market, there are various sandwich-type ELISA kits from several suppliers. On the other hand, a classical ELISA assay requires the application of two orthogonal antibodies of the analyte, which are not always easy to obtain [ 43 ]. In this study, we have substituted an ARC-inhibitor-based capture molecule for the capture antibody.…”
Section: Resultsmentioning
confidence: 99%
“…On the market, there are various sandwich-type ELISA kits from several suppliers. On the other hand, a classical ELISA assay requires the application of two orthogonal antibodies of the analyte, which are not always easy to obtain [ 43 ]. In this study, we have substituted an ARC-inhibitor-based capture molecule for the capture antibody.…”
Section: Resultsmentioning
confidence: 99%
“…We then evaluated the other components of the assay to negate any potential complications of interference or background due to the new buffer. Previous optimizations of ELISA-based methods 11 , 30 utilized a checkerboard titration system to test multiple antibody conditions on the same test plate. Using this process, we compared different assay conditions to optimize magsphere preparation methods as well as compare two distinct detection antibodies, each at varying concentrations.…”
Section: Resultsmentioning
confidence: 99%
“…Then, the OD value was obtained by a microplate reader in 15 mins. All the derivatives were set into two independent experimental groups, and the inhibition of GCPRs, which was expressed as a percentage, was based on these groups [ 50 , 62 , 63 , 64 ].…”
Section: Methodsmentioning
confidence: 99%