“…The importance o f this omission became obvious when later studies, using real components, showed that base conduction accounted for as much as 70% o f the total heat dissipation [77,102,103], As a result, more recent experimental studies by Arabzadeh et al [94], Nakayama and Park [104] and Tang and Ghajar [105] have addressed this issue by changing either the conductive resistance between the module base and substrate, or altering the substrate thermal conductivity to allow significant heat loss through the base. These studies highlighted that substrate conduction has a significant impact on module operating temperature, its thermal footprint size and substrate temperature gradients.…”