Abstract:The paper focuses on the die placement tolerance capability with critical design for land grid array (LGA) device evaluated on two different die attach machine platforms. The evaluation was narrowed down into two main die attach machines with the objective of attaining the best performance in terms of die placement tolerance capability. Die placement tolerance were quantified and only die attach Machine B was able to satisfy the specification of less than 30 microns. The study used a bar graph comparison in te… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.