2009
DOI: 10.1016/j.snb.2009.06.040
|View full text |Cite
|
Sign up to set email alerts
|

Different calibration methods of a microbial BOD sensor for analysis of municipal wastewaters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 26 publications
0
9
0
Order By: Relevance
“…Microorganisms are entrapped on columns [35] or immobilized on membranes [36][37][38][39][40][41][42][43]. The microorganisms used are pure strains with or without enzymes [36][37][38][39], consortia of mixed strains , or inocula from wastewater-treatment plant (WWTPs) [39,40], synthetic wastewater [41], brackish waters [43] or standardized microbial cultures [42]. Inocula metabolize a broader spectrum of substrates but present a less stable composition and are consequently less constant over time.…”
Section: Clark Electrodementioning
confidence: 99%
See 1 more Smart Citation
“…Microorganisms are entrapped on columns [35] or immobilized on membranes [36][37][38][39][40][41][42][43]. The microorganisms used are pure strains with or without enzymes [36][37][38][39], consortia of mixed strains , or inocula from wastewater-treatment plant (WWTPs) [39,40], synthetic wastewater [41], brackish waters [43] or standardized microbial cultures [42]. Inocula metabolize a broader spectrum of substrates but present a less stable composition and are consequently less constant over time.…”
Section: Clark Electrodementioning
confidence: 99%
“…Inocula metabolize a broader spectrum of substrates but present a less stable composition and are consequently less constant over time. Furthermore, while dynamic measurements offer a quicker response and a broader detection area, steady-state measurements give reliable results in the concentration range 15-50 mgO 2 /L [40]. BOM can also be monitored in anaerobic processes [44].…”
Section: Clark Electrodementioning
confidence: 99%
“…However, it is hard to be put into pilot scale or practice because of its limitation in volume size, which greatly hinder the development of MFCs in heavy metal treatment and power generation. So researchers explore the potentials of MFCs as a biosensors [6][7][8][9][10][11][12], which do not require a physical or chemical converter and has the characteristics of biosensors, also is easier to achieve the formation as an on-line monitoring biosensor [13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…doi:10.1016/j.bios.2010.06.040 employed as the sensor response. This transient state measurement has been employed not only for the batch system (Riedel et al, 1988;Tan et al, 1993;Velling and Tenno, 2009), but for the flow system (Sohn et al, 1995;Sangeetha et al, 1996;Yang et al, 1997;Riedel et al, 1998;Liu et al, 2000Liu et al, , 2004aChan et al, 2000).…”
Section: Introductionmentioning
confidence: 99%