2006
DOI: 10.1016/j.jclinane.2005.06.004
|View full text |Cite
|
Sign up to set email alerts
|

Different effects on circulatory control during volatile induction and maintenance of anesthesia and total intravenous anesthesia: autonomic nervous activity and arterial cardiac baroreflex function evaluated by blood pressure and heart rate variability analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

6
31
1

Year Published

2009
2009
2019
2019

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 50 publications
(38 citation statements)
references
References 34 publications
6
31
1
Order By: Relevance
“…Sevoflurane is reported to decrease both HF and LF [6,8,9]. These results are consistent with our present study.…”
Section: Discussionsupporting
confidence: 94%
“…Sevoflurane is reported to decrease both HF and LF [6,8,9]. These results are consistent with our present study.…”
Section: Discussionsupporting
confidence: 94%
“…Within a multimodal framework including EEG, cardiovascular and respiratory assessment, we have devised a point process framework able to successfully characterize the variations in heartbeat dynamics when applied to PROP and DMED administration protocols. Previous results from our groups and other authors have stressed the importance of dynamic autonomic monitoring during anesthesia, and particularly during PROP and DMED [13,15,19,20,34,44,[46][47][48]51,53,54,72,73,75]. In this presentation, we provide further evidence that our refined methods for analyzing the heartbeat dynamics during administration of specific anesthetic drugs are able to overcome nonstationary limitations, thus providing new real-time monitoring approaches to patients receiving anesthesia.…”
Section: Discussionsupporting
confidence: 52%
“…A recent review article by Mazzeo and colleagues [34] summarizes some of the most relevant findings and limits of HRV as a diagnostic and prognostic tool in anesthesia and concludes that 'investigation of HRV as a method of monitoring the depth of anesthesia, assessing the response to painful stimuli, did not yield uniform results and needs more extensive investigations.' Several other important studies have considered HRV to quantify anesthesia [35][36][37][38][39][40][41][42][43][44][45][46][47][48][49][50][51], demonstrating the usefulness of HRV measures. In particular, time-varying identification methods have provided successful characterization of PROP and DMED effects on the ANS [19,20,24,28,44,51].…”
mentioning
confidence: 99%
“…[22] Furthermore, a decrease in blood pressure variability has been reported with volatile induced and maintenance anesthesia that has not been reported with total intravenous anesthesia. [23] Although the postoperative inotropic needs and morbidity rates were similar in our study, the use of DEX effectively attenuated the systolic blood pressure variability and also achieved more stable hemodynamics throughout the operation. In addition, while postoperative mortality and morbidity were similar in both groups, more stable hemodynamics may provide lower cardiac and systemic complications in patients with limited cardiac reserve.…”
Section: Discussionmentioning
confidence: 47%