Digital image correlation for full-field time-resolved assessment of arterial stiffness

Abstract: Abstract. Pulse wave velocity (PWV) of the arterial system is a very important parameter to evaluate cardiovascular health. Currently, however, there is no golden standard for PWV measurement. Digital image correlation (DIC) was used for full-field time-resolved assessment of displacement, velocity, acceleration, and strains of the skin in the neck directly above the common carotid artery. By assessing these parameters, propagation of the pulse wave could be tracked, leading to a new method for PWV detection b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 37 publications
0
8
0
Order By: Relevance
“…In one of the first in - vivo studies on live human tissue, Campo et al . 16 compared the recorded pulse wave velocity (PWV) of the arterial system using DIC and ultrasound. According to their findings, PWV measurements from both methods were more or less similar in values.…”
Section: Introductionmentioning
confidence: 99%
“…In one of the first in - vivo studies on live human tissue, Campo et al . 16 compared the recorded pulse wave velocity (PWV) of the arterial system using DIC and ultrasound. According to their findings, PWV measurements from both methods were more or less similar in values.…”
Section: Introductionmentioning
confidence: 99%
“…Then, we present the superiorities of the improved WTP method by comparing the accuracy and efficiency of applications to varying complexions. Moreover, we validate this body sensor by measuring the pulse wave velocity (PWV) of human carotid artery, 37,38 and further suggest promising applications in the discussion and conclusion.…”
Section: Introductionmentioning
confidence: 71%
“…Using the 4-channel vibrometer, displacement of the vessel wall could be tracked in specimens 1 and 2. Out-of-plane displacements of the first maximum of upstroke are 10-100 μm which is comparative to skin displacements above the CCA in a human subject [13]. By tracking the 50% of maximum upstroke, the PWV can be determined.…”
Section: A Specimens 1-2mentioning
confidence: 98%