Dosimetric characteristics of Novalis shaped beam surgery unit

Abstract: The dosimetric characteristics of a new dedicated radiosurgical treatment unit are systematically measured in terms of its percent depth dose, beam profile, and relative scatter factor. High-resolution diode detector, mini-ion-chamber detector, and conventional Kodak XV films are used to measure dosimetric data for a range of field sizes from 6x6 mm to 100x100 mm. The effects of collimator size, micro-multileaf collimator shape, and detector type on the dosimetric data are investigated. Results indicate that, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
57
1
1

Year Published

2003
2003
2017
2017

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 80 publications
(64 citation statements)
references
References 7 publications
5
57
1
1
Order By: Relevance
“…Evaluations of many commercially available detectors have been published with correction factors for small‐field dosimetry 22. A practical measurement methodology for validating small‐field beam data using multiple detectors has also been reported 23. A newly published code of practice from the International Atomic Energy Agency24 is also a useful guideline.…”
Section: Acceptance Testing and Commissioningmentioning
confidence: 99%
“…Evaluations of many commercially available detectors have been published with correction factors for small‐field dosimetry 22. A practical measurement methodology for validating small‐field beam data using multiple detectors has also been reported 23. A newly published code of practice from the International Atomic Energy Agency24 is also a useful guideline.…”
Section: Acceptance Testing and Commissioningmentioning
confidence: 99%
“…The mechanical isocenter accuracy of the C‐arm linac has reached submillimeter levels 8 , 9 . The flattening filter was first redesigned to be more efficient and later completely removed in order to deliver higher dose rates 10 , 11 . The multileaf collimators' (MLC) leaf resolution is also improving, with 2.5 mm leaf widths at the isocenter, in order to improve the dose conformality to the target (12) .…”
Section: Introductionmentioning
confidence: 99%
“…( 30 ) On the other hand, the published maximum leaf speed is 1.5 cm/sec. ( 19 ) The 2.0 cm/sec speed was expected to be close to the maximum achievable. The results are presented in Table 4.…”
Section: Resultsmentioning
confidence: 90%
“…The unit is equipped with a permanently mounted mMLC. ( 19 ) It has 26 leaf pairs moving along the Y‐jaw direction. The leaves have different widths, the thinnest ones in the center projecting to the isocenter at 3 mm.…”
Section: Methodsmentioning
confidence: 99%