2017
DOI: 10.1038/s41598-017-14629-w
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric comparison of the helical tomotherapy, volumetric-modulated arc therapy and fixed-field intensity-modulated radiotherapy for stage IIB-IIIB non-small cell lung cancer

Abstract: The study aimed to compare the dosimetric parameters to target dose coverage and the critical structures in the treatment planning of helical tomotherapy (TOMO), volumetric-modulated arc therapy (VMAT), and fixed-field intensity-modulated radiotherapy (IMRT) for NSCLC delivering conventionally fractionated radiotherapy. Thirty patients with pathologically confirmed NSCLC were included. Three radiation treatment plans were designed for each patient. All patients received the uniform prescription dose of 60 Gy t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

2
10
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 30 publications
2
10
2
Order By: Relevance
“…Some literatures reported that VMAT achieved higher dose conformity of PTV and better sparing of OARs with a shorter treatment delivery time than FF-IMRT in comparison with plans of different cancers [25][26][27]. In our present study, compared with FF-IMRT plans, VMAT were also exhibited better dose distribution of target and better sparing of OARs.…”
Section: Discussionsupporting
confidence: 65%
“…Some literatures reported that VMAT achieved higher dose conformity of PTV and better sparing of OARs with a shorter treatment delivery time than FF-IMRT in comparison with plans of different cancers [25][26][27]. In our present study, compared with FF-IMRT plans, VMAT were also exhibited better dose distribution of target and better sparing of OARs.…”
Section: Discussionsupporting
confidence: 65%
“…Furthermore, a more tangible dose distribution can be obtained. Similar studies on tumors in other systems have shown that HT is superior to IMRT or VMAT or 3Dconformal radiotherapy in OARs, conformity, and homogeneity [34,35].…”
mentioning
confidence: 61%
“…Growing Evidences have shown that HT can sculpt radiation doses to complex-shaped tumorous regions and avoid high-dose regions to OARs through the rapid opening and closing of leaves in a collimator rotating around the patient [22]. Therefore, HT is frequently used in various diseases [23][24][25][26], including NPC and CC [27,28], nowadays. In this study, results showed that the three IMRT techniques met the clinical demand, but HT showed an evidently sharp dose gradient with the optimal HI and CI in NPC and CC.…”
Section: Discussionmentioning
confidence: 99%
“…Compared with FF-IMRT and HT, VMAT reduced the treatment delivery time by 37.5% and 55.0%, respectively, in CC and by 41.3% and 42%, respectively, in NPC. Several studies have reported that VMAT has achieved higher dose conformity of PTV and better sparing of OARs with a shorter treatment delivery time than FF-IMRT in terms of plans of different cancers [38][39][40]. Shortened treatment time may reduce the in uence of uncertain factors, the probability of patients' movement, and patients' discomfort.…”
Section: Discussionmentioning
confidence: 99%