2013
DOI: 10.1016/j.jcrc.2013.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic evaluation of near-infrared peripheral oximetry in healthy volunteers: A comparison between INVOS and EQUANOX

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

4
18
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(23 citation statements)
references
References 19 publications
4
18
0
Order By: Relevance
“…Fellahi and colleagues also found significantly greater rates of rSO 2 change during desaturation (3.65%/min vs 2.36%/min) and resaturation (30.4 vs 16.8%/min) for INVOS compared with EQUANOX, similar to our own findings [16]. But Hyttel-Sorensen and colleagues reported a steeper desaturation slope with EQUANOX during arm vascular occlusion in 10 healthy volunteers compared with INVOS and FORE-SIGHT [19].…”
Section: Discussionsupporting
confidence: 85%
See 2 more Smart Citations
“…Fellahi and colleagues also found significantly greater rates of rSO 2 change during desaturation (3.65%/min vs 2.36%/min) and resaturation (30.4 vs 16.8%/min) for INVOS compared with EQUANOX, similar to our own findings [16]. But Hyttel-Sorensen and colleagues reported a steeper desaturation slope with EQUANOX during arm vascular occlusion in 10 healthy volunteers compared with INVOS and FORE-SIGHT [19].…”
Section: Discussionsupporting
confidence: 85%
“…Fellahi and colleagues found a greater percent maximum difference from baseline with INVOS compared with EQUANOX in healthy subjects during leg vascular occlusion tests [16]. In 42 off-pump coronary artery bypass surgery patients, Moerman and colleagues reported a greater area under the curve for INVOS during desaturation compared to FORE-SIGHT (−68%/s vs −39%/s) and only a weak correlation in rSO 2 values between the two devices ( r  = 0.31) [17].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Past studies comparing NIRS monitors have highlighted discrepancies in the values obtained at rest and during exercise in human [11][12][13][14] and animal 15 systems. The differences between monitors are likely to be in part associated with the measurement site and spacing of the probes.…”
Section: Introductionmentioning
confidence: 99%
“…These different machines may yield discrepancies in the values obtained and lead to altered interpretation of those values. Differences between NIRS monitors and location of oxygen probes have been found in human medicine . However, there are limited studies in veterinary medicine.…”
Section: Introductionmentioning
confidence: 99%